23
TriStar MPPT 600V Operator’s Manual
22
Installation
7
8
9
10
Figure 3-4. Knock-outs, bottom view
12
11
Figure 3-5. Knock-outs, back view
Item
Quantity
Trade Size
Hole Dimension
Circuit(s)
Pass-Through?
1
2 (Concentric)
1” & 3/4”
1.36“ (34.5 mm) / 1.09” (27.8 mm)
Solar (high voltage)
YES
2
2 (Concentric)
1-1/4 “ & 1 “
1.72” (43.7 mm) / 1.36“ (34.5 mm)
Battery (low voltage)
YES
3
4
Fits select MC-style
Solar connectors **
18 mm
Solar (high voltage)
NO
4
3
1/2” or M20
7/8” (22.2 mm)
Solar (high voltage)
NO
5
1
1/2” or M20
7/8” (22.2 mm)
Communication
YES
6
1
1.36“ (34.5 mm)
Communication
YES
7
2 (Concentric)
1-1/4 “ & 1 “
1.72” (43.7 mm) / 1.36“ (34.5 mm)
Battery (low voltage)
NO
8
2 (Concentric)
1” & 3/4”
1.36“ (34.5 mm) / 1.09” (27.8 mm)
Solar (high voltage)
NO
9
4
1/2” or M20
0.88” (22.2 mm)
Solar (high voltage)
NO
10
4
1/2” or M20
0.88” (22.2 mm)
Battery (low voltage)
NO
11
2
3/4”
1.09” (27.8 mm)
Solar (high voltage)
NO
12
2
1”
1.36“ (34.5 mm)
Battery (low voltage)
NO
** Solar connector mounting hole diameters vary. Wieland Solar DC connectors recommended.
Table 3-1. Knock-out sizes
Solar Wiring
Battery Wiring
Communication
Wiring
Figure 3-6. Wiring pass-through paths between multiple controllers
3.4 Controller Preparation (TS-MPPT-60-600V-48 and
TS-MPPT-60-600V-48-DB)
Step 1 - Remove the Wiring Box Cover
CAUTION: Shock Hazard
Disconnect all power sources to the controller before removing the wiring box cover. Never
remove the cover when voltage exists on any of the TriStar MPPT 600V power connections.
PRUDENCE : Risque de décharge électrique
Déconnectez toutes les sources d’alimentation du contrôleur avant d’enlever le couvercle
du boîtier de câblage. Ne retirez jamais le couvercle en présence de tension sur une des
connexions d’alimentation du TriStar MPPT 600V 600V600V.
!
!