![Morningstar TRAKSTAR TS-MPPT-60-600V-48 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/morningstar/trakstar-ts-mppt-60-600v-48/trakstar-ts-mppt-60-600v-48_manual_1834370043.webp)
85
TriStar MPPT 600V Operator’s Manual
84
10.0 Appendix
OVER-
VOL
TA
GE R
ANGE
Vb = 40 V
Vb = 50 V
15A INPUT CURRENT LIMIT
60 Amp Battery Current Limit
60 Amp Battery Current Limit
Vb = 30 V
60 Amp Battery Current Limit
Vb = 20 V
60 Amp Battery Current Limit
60 Amp Battery Current Limit
Vb = 60 V
0
100
200
300
400
500
600
500
1000
1500
2000
2500
3000
3500
INPUT VOLTAGE (Volts)
POWER (
W
atts)
Output Power vs. Array Input Voltage
Figure 10-3. Output Power vs. Array Voltage
84
86
88
90
92
94
96
98
100
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000
E
ffi
ci
en
cy (%)
E
ffi
ci
en
cy (
%)
E
ffi
ci
en
cy (%)
Power Output (W)
Power Output (W)
Power Output (W)
300 Vmp, 52 Vba
tt
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700
2800 2900 3000
400 Vmp, 52 Vba
tt
-
80
82
84
86
88
90
92
94
96
0
10
0
20
0
30
0
40
0
50
0
60
0
70
0
80
0
90
0
10
00
11
00
12
00
13
00
14
00
15
00
16
00
17
00
18
00
19
00
20
00
200 Vmp, 52 Vba
tt
Figure 10-4. Efficiency Curves
Efficiency