B-20 REGULAR INSPECTION
13.
CHANGING FLUID OF HYDRAULIC TANK
Change the hydraulic fluid in the hydraulic unit tank at regular intervals while paying attention to
the following considerations.
(1) Maintain the oil level of hydraulic fluid in the tank at the correct level; make sure
that the pump unit does not suck in air.
(2) Keep the hydraulic fluid clean.
(3) Clean the strainer periodically to avoid clogging which will lower the pump flow
rate.
<Changing interval>
Every 1000 hours of operation
<Procedure>
1) Turn OFF the main power.
2) Remove the fill port cap.
3) Place a drain pan beneath the drain plug.
4) Remove the drain plug and drain oil in the tank.
Place a drain pan beneath the drain plug on the oil pan and remove both drain plugs on
the hydraulic unit and oil pan.
5) Wrap sealing tape around the threaded section of the plug.
6) Replace the drain plug.
7) Supply oil while checking the oil level gage.
CAUTION
NOTE
Oil level gage
Drain plug
Sealing tape
Drain pan
Fill port cap