REGULAR INSPECTION B-5
4.
CLEANING THE ELECTRICAL CABINET AIR FILTER
The electrical cabinet is not cooled directly by outside air; it is cooled indirectly through heat
exchange between outside air, taken into the cabinet through the duct, and inside air.
Therefore, if the air filter at the air suction port is clogged, the inside of the electrical cabinet will
not be cooled satisfactorily.
<Cleaning interval>
Every 50 hours of operation
<Procedure>
1) Turn off the power.
2) Remove the filter cover from the electrical cabinet.
3) Clean the filter using neutral detergent.
4) Dry the filter.
5) Mount the filter cover in the electrical cabinet.
6) Turn on the power.
The shape of the electrical cabinet air filter may
differ depending on the machine model.
Air filter
Filter cover
NOTE