A-4 DAILY INSPECTION
3.
LUBRICATING AND HYDRAULIC OIL
1. Always use oil types specified by Mori Seiki.
Do not mix different brands of oil even when identified as being of "equivalent"
quality. When changing to a different brand of oil, drain all original oil from the tank
completely, clean the inside of the tank, and add replacement oil.
Mori Seiki is not responsible for problems arising from the mixture of different
brands of oil or the use of non-specified oils.
2. The customers themselves must receive an MSDS (safety data sheet for e.g.
chemical substances) for oils such as coolant (cutting fluid) and the various
lubricants and cooling oils, and the customer must take responsibility for securing
and managing the working environment, and for managing disposal of the oils.
Take careful note of the effects on the human body described in the MSDS.
For the type of oil to be used and tables comparing the oils produced by different
manufacturers, refer to the OILING CHARTS and the Oil Recommendations in the
MAINTENANCE INFORMATION published separately.
3.1
Storing Oil
If obtaining large amounts of oil for storage, observe the following points to prevent oil
degradation. Obtaining limited amounts of oil only as required is strongly recommended.
Obtaining limited amounts of oil only as required is strongly recommended.
(1) Store oil in locations free from direct sunlight or rain.
(2) Keep oil clean. Foreign matter or water should not be allowed to enter the oil storage tank.
(3) Never use degraded oil or oil contaminated by foreign matter or water.
(4) If a storage tank is used, remove foreign matter and water from the tank at least once a year.
3.2
Cautions When Replenishing Oil
When replenishing oil, observe the following points:
(1) Always use the same oil can for specific oil brands. Never use a can used for a different
brand of oil.
(2) Never remove the filter from the filter port of each tank when supplying oil.
If oils other than those specified by Mori Seiki are used mistakenly or different brands
of oil are mixed, clean the tank and flush piping immediately.
CAUTION
CAUTION
Содержание MSC-500
Страница 6: ...CHAPTER A DAILY INSPECTION...
Страница 27: ...CHAPTER B REGULAR INSPECTION...
Страница 63: ...B 34 REGULAR INSPECTION 6 Unplug the cable connector 7 Mount a new printed circuit board...