46
MB300 XL Pro
rev.0.2 ID03570
7. OPERATION AND USE
7.1 PREPARATION OF THE MACHINE
7.1.1 GLUE TANK LOADING
The glue tank must be filled in the case in which the amount of glue is less than the minimum level
imprinted on the tank.
CAUTION!
Wear face, hand, protection, mask suitable for using glue and
protective goggles.
CAUTION!
Never open the tank when it is COLD.
Possibility of breakage of the sealing gaskets and ageing and premature (curing)
of the glue with probable clogging and maintenance requirements.
CAUTION!
Only glue of the same Type and Brand must be added to the tank.
A new type of glue is only inserted when the glue unit is completely empty and
cleaned with Blu-Cleaner.
CAUTION!
With Polyurethane glue do not leave the tank open for more than 10
minutes.
CAUTION!
Never fill the tank with more than 3kg of glue.
To access the glue tank you have to open the sliding door provided with handle.
The opening of this protection sends the machine into a state of emergency and discharges the
pressure of the glue tank while the Cleaner tank remains at a pressure of about 2 bar.
The machine can not work with the back door open.
Содержание MB300 XL Pro
Страница 1: ...MB300 XL Pro rev 0 2ID03570 OPERATOR MANUAL Translation of the original instructions ...
Страница 82: ...82 MB300 XL Pro rev 0 2ID03570 ...
Страница 83: ...83 MB300 XL Pro rev 0 2ID03570 ...
Страница 84: ......