Manual Part No: 930154-01
MD Electric Grill
- 8 –
Manual Rev No: 1
INSTALLATION
Important
This appliance
MUST
be installed by a competent person in accordance with these and any other relevant
regulations.
The installation wiring
MUST
comply with the latest I.E.E. Regulations.
WARNING: THIS APPLIANCE MUST BE ELECTRICALLY EARTHED
.
Before Installation
Before commencing installation, remove all packaging materials from the appliance. It is suggested that
any protective film adhering to the stainless steel panels should be left on until installation is completed.
BUT THIS MUST BE REMOVED BEFORE COMMISSIONING OR OPERATING THE APPLIANCE.
Check the appliance Data Plate (fitted to the back panel), to ensure that the appliance is suitable for the
electricity supply available.
Ensure that the floor upon which the appliance is to stand is level and capable of adequately supporting
the weight of the appliance.
TO COMPENSATE FOR SOME UNEVENNESS OF THE FLOOR, THE
APPLIANCE FEET ARE ADJUSTABLE.
THE FLOOR MUST BE FIRE PROOF
. If it is not, or if any adjacent wall or surface is made of a combustible
material, then the installer must ensure that the requirements of the
LOCAL FIRE REGULATIONS
are
observed.
Positioning
The grill may be mounted on a floor stand (page 12), on a bench stand (page 10), on wall brackets (page
11) or above a range (page 13 & 14).
The grill should be positioned clear of any adjacent walls by a minimum of 150mm (6”) on all sides. It is
also recommended that a minimum distance of 450mm (17.7”)* be allowed between the top of the
appliance and any shelf or ceiling.
*This distance
MUST
be 600mm (24”) when the ceiling or overshelf is made from combustible material.
There should be a minimum distance of 430mm (17”) between the bottom of the appliance and any solid
or open top burners below.
It is recommended that the appliance be sited below a ventilating hood, one preferably connected to an
extractor system incorporating a grease filter.
Ensure that the appliance is level in two places - front to rear and side to side. To check the level it is
recommended that a spirit level be placed on the toast rack