CPT

The Interface Solution Experts

PC-Programmable Signal
Isolater/Converter

The CPT 

The CPT is a PC-Programmable, user-confi gurable, 
transmitter.   The instrument includes an analog output 
and an optional alarm (relay) output.  The alarm can 
be confi gured as a trip or fault alarm.  The CPT has 
a READY LED to indicate the health of the unit, an 
INPUT LED  to indicate the status of the input and a 
dual color LED to indicate alarm status.

Model and Serial Numbers

Moore Industries uses a system of model and serial 
numbers to keep track of all of the information on    
every unit it sells and services.  If a problem occurs 
with your CPT, check for a tag affi xed to the unit 
listing these numbers.  Supply the Customer Support 
representative with this information when calling.

Inputs

The current input range of your unit  is from 0 – 50mA.  
The voltage input range is from 0.0 – 10V. 

Outputs

The CPT has a factory confi gurable current or voltage 
output.  The curent output range is 0-20mA.  The 
voltage output is 0-10V.  An Analog Output (-AO) is 
standard.  The current output is a factory confi gurable 
sink or source.  Please notify Moore Industries 
of your required confi guration.  The output may 
also be confi gured to narrower spans from the PC 
Confi guration Program.

TX Power
A transmitter excitation power supply is standard on 
the CPT (HLPRG).  You may access this at the TX and 
COM terminals.  This is a fi xed power supply at 23Vdc, 
±3% and 24mA max. 

Options

Relay Output (-C)
An optional Relay Output (-C) is available.  This is 
a one relay output with 5A@250Vac or 5A@24Vdc, 
50/60Hz  non-inductive contact rating.  The relay 
contact arrangement is SPDT.  All relay contacts (NO, 
NC and COM) are available for use.  No jumpers are 
required.

RF Option (-RF)
An RF option is also available.  This version provides 
30V/m RFI/EMI immunity compared to our standard 
model which offers 10V/m RFI/EMI immunity.

Introduction

This is the users’ manual for the Moore Industries 
CPT PC-Programmable Transmitter  (HLPRG: Volt and 
Milliamp input limits).  It contains all of the information 
needed to confi gure, install, operate, and maintain this 
instrument.  

About this Manual

Wherever you see a “ Note”, “ Caution”, or “ WARNING 
” pay particular attention.

WARNING - Hazardous procedure or condition that 
could injure the operator.

Caution - Hazardous procedure or condition that could 
damage or destroy the unit.

Note - Information that is helpful for a procedure, 
condition, or operation of the unit.

Figure 1. The CPT (HLPRG)

INPUT

READY

ALARM

COM

COMPUTER 
PROGRAMMABLE 
TRANSMITTER

Содержание CPT HLPRG

Страница 1: ...CPTMay 2016 225 708 00 D PC Programmable Signal Isolater Converter All product names are registered trademarks of their respective companies CPT HLPRG PC Programmable Signal Isolater Converter...

Страница 2: ...s 6 Configuring the CPT 7 Installing the Configuration Software 8 Connecting the CPT to the PC 8 PC Configuration Software Summary 9 Configuration 10 Output Level if Failure 10 Broken Wire Test Overri...

Страница 3: ...Custom Table 16 Installation 17 Mounting the CPT 17 Making the Electrical Connections 17 Recommended Ground Wiring Practices 17 CE Conformity 17 Operation 17 Maintenance 17...

Страница 4: ...figuration The output may also be configured to narrower spans from the PC Configuration Program TX Power A transmitter excitation power supply is standard on the CPT HLPRG You may access this at the...

Страница 5: ...cal 3W max Power Supply Effect 0 002 of span per 1 of line change Input Impedance 20ohms for current inputs 1 1Mohm for voltage inputs Input Over Range Protection 100mA for current inputs 30Vdc for vo...

Страница 6: ...KEY AC DC Power Input ACC DCC Power Input CM Relay Common COM Analog Common GND Ground NOTES 1 Terminal blocks can accomodate 14 22 AWG solid wiring 2 NO CM NC labeling is present only when the unit i...

Страница 7: ...igent PC Configuration software The software settings are downloaded to the transmit ter in the form of a Configuration File and stored in the instruments memory You can save a backup copy of the file...

Страница 8: ...mitter and most parameters can be set without benefit of input from a CPT This makes it easy to create a set of operating parameters save them to disk and download them to one or more transmitters at...

Страница 9: ...ou may enable Start Measurements and Stop Measurements upload your configuration to PC or download your configuration to the unit save your configuration to a file and print out your configuration set...

Страница 10: ...3 6mA upscale for voltage outputs limits are 0 5V downscale and 11 0V upscale When a failure is detected the Fail Last feature if enabled holds the last measured value before the failure occurred If t...

Страница 11: ...re energized whenever the process input is in an alarm condition These relays de energize when the process input returns to the reset point including any deadband Band Alarm The Band Alarm incorporate...

Страница 12: ...verifies that the input from the sensor to the alarm is being interpreted correctly The CPT can trim any point along the scale Note that one point trimming applies an offset to the sensor reading whi...

Страница 13: ...grammable Signal Isolater Converter Figure 7 Trimming the CPT HLPRG MULTIMETER OR DCS NO INPUT READY ALARM COM COMPUTER PROGRAMMABLE TRANSMITTER VOLTAGE SOURCE _ CURRENT SOURCE _ _ AC OR DC POWER SUPP...

Страница 14: ...es stored click the Output Trim ON 5 Set Status back to Measurements On If selected the User trim values will be used and the manufacturer settings will be nullified Loop Test A Loop Test may be perfo...

Страница 15: ...he software 3 Insert a value between 5 and 120sec in the Damping Sec field This is the amount of time it will take for the output to reach 63 of the step output change once the input exceeds the value...

Страница 16: ...nts you are to set and insert this value into the Number Of Points line hit Enter This will highlight the number of points you have selected Note To clear the table and start over at any time click Cl...

Страница 17: ...ons Please refer to Figure 3 for electrical connections Recommended Ground Wiring Practices Moore Industries recommends the following ground wiring practices Any Moore Industries product in a metal ca...

Страница 18: ...nt packing material and carefully pack the equipment in a sturdy shipping contain er 5 Ship the equipment to the Customer Service Department nearest you The returned equipment will be inspected and te...

Отзывы: