- 24 -
MOONS’
MSSTAC6 Step Motor Drive User Manual
MOONS’
www.moons.com.cn
Connecting to the Aux Analog Input
The auxiliary analog input on the MSSTAC6 IN/OUT 2 connector can be used by Feed to Sensor
commands and other input functions when operating the drive in Host mode. The analog input can also be
read back to the Host using the IA immediate type and RA buffered type Host commands. Readings are in
Volts.
See Host Command Reference for more information.
+5 volt DC is provided for powering potentiometers. A 1000 to 10000 ohm potentiometer is
recommended and should be connected as shown below.
A 0 to 5 volt analog signal may also be used. Usually this signal comes from a PLC, a PC with data
acquisition card or a motion controller. Connections are shown below.
The +5V terminal is an output. Do not connect it to a power supply.
2.2
Configuration
STAC6 Configurator Software
The Configurator is used to configure MSSTAC6 drives for specific applications. The setup procedure is
divided into six sections, each focused on a particular area of configuration.
2.2.1
Configurator Menus
In the File Menu, previously created configurations can be Opened and new or altered configurations
can be Saved. Any setup can be Printed. The Exit command will close the ST Configurator.