Model 914-X Series Modular Multiplexer System User Manual
Focal Technologies Corporation
Page 5-3
A Moog Inc. Company
Document Number: 914-0601-00
Rev.
5.0
5.1
Installing the Model 914-X Series Diagnostic GUI
Check for the latest software release on the Moog Focal website:
http://www.moog.com/focal/914-x-series
search for 914-0401-00.
Install the software on a computer with Microsoft Windows 7 (or newer Microsoft OS) and a serial (COM) port
connected to the 914-HDE diagnostic port. Microsoft .NET version 4.0 or greater must be installed on the host
computer. Installation of the Model 914 diagnostic GUI will involve copying the compressed software package to a
local drive, th
en uncompressing to “C:\Focal\”. Follow the instructions in the “Installation.txt” file and open the
"Model914.exe" file. Once installed, open the software and press the (+) at the top left corner to set up the COM
link.
The following section is an overview of the diagnostic GUI.
Figure 5-4: Diagnostic GUI Start Screen
Once the COM port is setup, press “Start Data Refresh” at the bottom of the screen.
If a successful link to the 914-HDE is established, a green heart will be seen at the top left of the screen near the
COM port listing. If the heart appears red, the link has not been established. Verify the COM port number and the
wiring harness to the PCBA and ensure power is applied to the 914-HDE.