Supported/Not-Supported Functionality
l
function is one of the following codes:
function
Description
0
Set IP address
1
Set subnet mask
2
Set gateway
l
"string" is formatted as an IP address and entered as a string
For example:
IPCTL
(0,"192.168.0.10")
'Set the IP address to 192.168.0.10
For more details on the IPCTL command, see the
SmartMotor™ Developer's Guide
. For details
on the Ethernet and USB ports, see the
Class 6 SmartMotor™ Installation & Startup Guide
.
Supported/Not-Supported Functionality
Supported Functionality
A small set of functions are supported for access to these basic SmartMotor operations:
l
Report commands: RPA, RSP, etc.
Report commands are shown in the
SmartMotor Developer's Guide
. They can be
identified by looking at the command lists (near the end of the guide) for commands
that begin with a superscript "R" character, for example:
R
PA,
R
SP,
R
PC etc.
Commands that begin with an "R" character that
is not
superscript
are not
report
commands, for example: RANDOM=, RESUME, RETURN, RETURNI, RUN, RUN?.
NOTE:
Also, refer to the Not-Supported Functionality section.
For more details, refer to Example with a String Response on page 24 and Example with
a Numeric Response on page 25.
l
Assign a variable: a=400
For more details, refer to Example of Assigning a Variable on page 26.
Moog Animatics Class 6 SmartMotor™ Ethernet Serial Encapsulation Guide, Rev. B