background image

XT0016

Installation & Maintenance Manual

•  The installation of this fireplace must be done by a 

qualified and certified gas appliance installer.

•  Check local codes and read all instructions prior to 

installation.

®

C

US

       WARNING:

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, 

death, or property damage.

— Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Leave the building immediately.
•  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

— Installation and service must be performed by a qualified 

installer, service agency or the gas fitter.

PROFLAME 2 UPGRADE KIT  

RX 200 + RX 300 NG/LP

 

Upgrade Kit NG/LP Proflame 2 

 

(Basic to Full Load with Remote)

THIS KIT IS FOR USE WITH THE FOLLOWING MODELS: 

RX200:

B34DT-2-F : B34 TOP VENT, ELECTRONIC IGNITION, IPI
B34DR-2-F : B34 REAR VENT, ELECTRONIC IGNITION, IPI
B38DT-2-F : B38 TOP VENT, ELECTRONIC IGNITION, IPI
B38DR-2-F : B38 REAR VENT, ELECTRONIC IGNITION, IPI
PL38DFN-F : PL38 , ELECTRONIC IGNITION, IPI
PL38DFL-F : PL38 , ELECTRONIC IGNITION, IPI
PL42DFN-F : PL42 , ELECTRONIC IGNITION, IPI
PL42DFL-F : PL42 , ELECTRONIC IGNITION, IPI
PL52DFN-F : PL52 , ELECTRONIC IGNITION, IPI
PL52DFL-F : PL52 , ELECTRONIC IGNITION, IPI

RX300:

DL6315NI : DL6315, ELECTRONIC IGNITION, IPI
DL6315STNI : DL6315ST, ELECTRONIC IGNITION, IPI

Ensure that all power to the appliance is off at the electrical breaker 

or fuse before beginning installation. Ensure gas is turned off at the 

shutoff valve before beginning installation.

When installing the fireplace - gas lines, fittings, accessories or any 

other objects cannot impede the proper movement of the door 

buckles.

CAUTION

WARNING

Some materials used in the manufacturing process of this product can 

expose you to Benzene which is known in the State of California to 

cause cancer and birth defects or other reproductive harm. For more 

information go to www.P65warnings.ca.gov

WARNING

Содержание Proflame 2 RX 300 LP

Страница 1: ...Load with Remote THIS KIT IS FOR USE WITH THE FOLLOWING MODELS RX200 B34DT 2 F B34 TOP VENT ELECTRONIC IGNITION IPI B34DR 2 F B34 REAR VENT ELECTRONIC IGNITION IPI B38DT 2 F B38 TOP VENT ELECTRONIC IGNITION IPI B38DR 2 F B38 REAR VENT ELECTRONIC IGNITION IPI PL38DFN F PL38 ELECTRONIC IGNITION IPI PL38DFL F PL38 ELECTRONIC IGNITION IPI PL42DFN F PL42 ELECTRONIC IGNITION IPI PL42DFL F PL42 ELECTRONI...

Страница 2: ...it RFK3002R or RFK3004R required 5 Battery backup for the main burner during power outage Before You Begin Ensure that the power supply has been turned off at the breakerorfusebeforebeginning the installation Shut off the gas supply at the shut off valve and ensure that the main burner and pilot light have been turned off and the fireplace has been cooled off for at least two hours before installa...

Страница 3: ... and Sensor Wire from connectors X2 and X3 of the control module 3 Disconnect the wall switch harness from X4 Control Module and discard 4 Remove the Valve Harness from X5 of the control module 5 Remove the connector from X1 of the control module 6 Remove the control module from firebox compartment and discard Note module is attached by velcro strips Figure 3 Powercord in PPO box Figure 4 Control ...

Страница 4: ...alve body Use a torque screw driver with Torx T20 bit to tighten the two screws to a torque setting of 25 lb in 5 5 Install the enclosed identification label to the valve body Figure 12 G Figure 11 Stepper Motor Installations Figure 12 Label Installation Figure 13 Identification Label NG Figure 14 Identification Label LP Figure 15 New Control Module Figure 16 X1 plug on control module 3 Connect th...

Страница 5: ...N OFF sticker supplied to the switch bracket E Battery Holder Installation 1 Secure the battery holder to the fireplace floor using the supplied velcro strips See Figure 22 Note The velcro strips act as an electrical isolation do not attach the battery holder to any metal part without using the velcro strips or the control module will be damaged 2 Connect the red and black wires from the battery h...

Страница 6: ...and ensure no leak 5 Turn the fireplace ON and modulate the flame using the remote control and ensure proper operation see Proflame 2 Operation and Maintenance Manual XG0677 Blue Back lit LCD display On Off Key Thermostat Key Up Down Arrow Key Mode Key Figure 24 Proflame Remote Control G Operation with MAIN Power 1 Remove the four batteries from the battery holder 2 Plug the Control Module Power c...

Страница 7: ...ially recovered asheatintothebuilding soitdoesnotwasteasmuchenergyasrunning a pilot in the off season A connector is supplied with this unit that can be plugged into the wire harness connected to the controller This Jumper Cable gives the Remote Control the ability to operate the CPI IPI switch and set the unittooperateineithercondition CPImeans ContinuousPilotIgnition or Standing Pilot as it is c...

Страница 8: ...WHITE GREEN Lights ON OFF CONTROL MAIN Power 120VAC 60 Hz 6 Amps SPARK SENSOR RED BLACK BATTERY PACK MAIN ON OFF SWITCH YELLOW GREEN PILOT R ORANGE GREEN BLACK BROWN YELLOW ORANGE 6 10 6 OPTIONAL CPI IPI SWITCH WHITE LED Lights LED1 Red LED LED2 Amber LED SW1 LED o tro e r LED power s pp y white white white BLACK WHITE VARIABLE SPEED COMFORT FANS Multicolored LED Lights Fan Kit only available in S...

Страница 9: ...place instructions 10 Loop Pilot wires from behind control board drawer to the front Plug into X2 and X3 8 Place Fan wire on leftside firebox floor with adhesive wire pad For fan Install instructions see Optional fan kit Install Replace instructions 11 Valve wires are plugged into the valve in the Green Red and yellow ports respectively Figure 24 e On Off switch through drawer Figure 24 i LED wire...

Страница 10: ...ting screws into the valve body Use a standard screwdriver or T20 Torx bit and tighten to the screws with a fixing torque of 251b in 5 IN THE EVENT THAT THE THREADS OF THE VALVE ARE STRIPPED OR DAMAGED REPLACE THE VALVE 7 Install the enclosed identification label G to the valve body where it can be easily seen 8 Make STEPPER MOTOR and valve electrical connections apply gas to system and relight ap...

Страница 11: ...XG2021 11 Notes ...

Страница 12: ...XT0016 Installation Maintenance Manual PROFLAME 2 UPGRADE KIT RX 200 NG LP RX 300 NG LP ...