background image

Page 7 of 13

MW38-BV  Modular Fireplace

XG0310 Rev. 01 - 11/98

Removing and Installing

 the Door

Removing the door surround:

The door surround is held in place by two metal clips at the top, and
one magnet on each side. To remove the surround, pull the bottom
outwards and lift upwards until the slots "A" are clear of tabs "B" in
the door. You may need to use a flat screwdriver to pull the door
surround outwards. 

(See figure 11a).

Installation

Removing and Installing

 the Insert

You may 

remove the insert

 to protect it from theft and damage

during construction.

1.

Remove the two machine screws (1 left & 1 right) at the top of the
insert that attach the insert to the shell.

 See figure 10, inset 1.

2.

Remove the 4 machine screws that hold the venting plate to the
insert. For easier access, you may remove the effiiciency baffles
to gain access to the venting plate.

3

. Remove the insert by tipping the top of the insert outward and

lifting the tabs past the slots in the bottom of the shell. 

See figure

10, inset 2.

Store the screws and clamps in a safe place to ensure that they are
not lost.

To 

re-install the insert

 simply reverse the steps above. 

Remember

to re-install the efficiency baffles if they were removed.

Removing the door:

Remove the machine screws along the top of the door, and then pull
the door outwards and upwards until it is clear of the door rail. 

(See

figure 11b).

 Ensure that a good seal is maintained when installing the

door.

Figure 10.

 

MW38-BV insert.

INSET 1

Tab

INSET 2

Mounting
Bracket

Figure 11a.

  Removing or installing the door surround.

Glass door
and frame

Door surround

Tab 'B'

Slot 'A'

Magnet

Pull bottom of door
surround outwards
and upwards.

Glass door
& frame

Figure 11b.

   Removing or installing the glass door.

Venting Plate

Front

Slot

Содержание MW38-BV

Страница 1: ...in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper insta...

Страница 2: ...ons If the optional air circulating fan kit is installed it must be electrically grounded in accordance with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA must...

Страница 3: ...rd clearance as specified by the manufacturer of the B Vent 14 33 41 35 38 28 35 14 4 4 Figure 1 Fireplace dimensions Figure 2 Framing dimensions When sheetrock is not used behind the fireplace framin...

Страница 4: ...may be connected to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 26 for wiring requireme...

Страница 5: ...he effects of elevated mantel temperatures which may be in excess of product design for example candles plastic or pictures This can cause melting deformation discoloration or premature failure of T V...

Страница 6: ...normal occurance Gas Control and Pilot Wiring MW38 BV I Honeywell Q3450 Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control SV9501M Gas Control Connector Fuse Limit Switch Wall Swi...

Страница 7: ...ess you may remove the effiiciency baffles to gain access to the venting plate 3 Remove the insert by tipping the top of the insert outward and lifting the tabs past the slots in the bottom of the she...

Страница 8: ...Model MW38 BV 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up lower brass trim 1 Turn off remote switch 2 Flip down lower brass trim 1 STOP Read the safety inform...

Страница 9: ...o light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn...

Страница 10: ...water Operation Lighting Instructions See pages 8 and 9 Burner Adjustment The Wildfire is equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the...

Страница 11: ...ve open Replace SV9500 SV9600 Check Transformer Line Volt Supply Replace SV9500 SV9600 Save old Igniter Flame Rod Assembly for service INSET HSI Terminals CHECK Line voltage power Low voltage transfor...

Страница 12: ...other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability Limitations On Liability Limitations On Liability...

Страница 13: ...el MW38 BV I 6 Aluminum Tubing 1 4 dia 7 Locking Nuts 8 Spacer 9 Bulkhead Fitting 10 90 Elbow 11 Burner Orifice 12 Burner Tube Available Options and Accessories 13 Add on Bay Window 14 Hand Held Remot...

Страница 14: ...Page 14 of 13 MW38 BV Modular Fireplace XG0310 Rev 01 11 98 Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0310 Rev 0 09 98...