background image

Page 5 of 13

MW38-BV  Modular Fireplace

XG0310 Rev. 01 - 11/98

Finishing Around the Fireplace

Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in 

Figure 6a

. Side wall clearances are 3".

Combustible surrounds may be installed with 3" clearance to the side
of the fireplace as shown in 

Figure 6b

.

Fireplace Facing

When selecting the finish material for your fireplace, it is important to
remember the following: 

BRASS TRIMS MUST NOT BE

OBSTRUCTED IN ANY WAY - to do so restricts the air supply for
the control compartments and heat exchanger it also prevents
access for servicing controls.

The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint.  Decorative facing must not
extend past the fireplace opening at all, because it will interfere with
the access to retainers for removal of glass door.

Installation

We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures.  This can cause
melting, deformation, discoloration or premature failure of T.V. and
radio components.

Sheetrock/

Drywall

Header

3

45

Painting:

Special care is recommended by the Master Painters and Decorators
Association, when painting the fireplace surrounds, to select and
apply a quality 

Alkyd sealer

 prior to the applying of latex paints.  This

is to prevent leaching of water from evaporation and causing a
brownish staining effect to paint over coats.

Top of fireplace

Combustible Facing

Combustible construction
allowed in shaded area.

1

2

3

4

5

6

7

8

9

10

11

12

Figure 6b.

 Combustible surrounds.

Figure 6a.

 Combustible mantles and facings.

Mantels & Surrounds

NOTE:

 National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.

New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.

Please be aware; temperatures over the mantel will rise above
normal room temperature and walls above fireplace may be hot to
touch.

Содержание MW38-BV

Страница 1: ...in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper insta...

Страница 2: ...ons If the optional air circulating fan kit is installed it must be electrically grounded in accordance with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA must...

Страница 3: ...rd clearance as specified by the manufacturer of the B Vent 14 33 41 35 38 28 35 14 4 4 Figure 1 Fireplace dimensions Figure 2 Framing dimensions When sheetrock is not used behind the fireplace framin...

Страница 4: ...may be connected to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 26 for wiring requireme...

Страница 5: ...he effects of elevated mantel temperatures which may be in excess of product design for example candles plastic or pictures This can cause melting deformation discoloration or premature failure of T V...

Страница 6: ...normal occurance Gas Control and Pilot Wiring MW38 BV I Honeywell Q3450 Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control SV9501M Gas Control Connector Fuse Limit Switch Wall Swi...

Страница 7: ...ess you may remove the effiiciency baffles to gain access to the venting plate 3 Remove the insert by tipping the top of the insert outward and lifting the tabs past the slots in the bottom of the she...

Страница 8: ...Model MW38 BV 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up lower brass trim 1 Turn off remote switch 2 Flip down lower brass trim 1 STOP Read the safety inform...

Страница 9: ...o light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn...

Страница 10: ...water Operation Lighting Instructions See pages 8 and 9 Burner Adjustment The Wildfire is equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the...

Страница 11: ...ve open Replace SV9500 SV9600 Check Transformer Line Volt Supply Replace SV9500 SV9600 Save old Igniter Flame Rod Assembly for service INSET HSI Terminals CHECK Line voltage power Low voltage transfor...

Страница 12: ...other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability Limitations On Liability Limitations On Liability...

Страница 13: ...el MW38 BV I 6 Aluminum Tubing 1 4 dia 7 Locking Nuts 8 Spacer 9 Bulkhead Fitting 10 90 Elbow 11 Burner Orifice 12 Burner Tube Available Options and Accessories 13 Add on Bay Window 14 Hand Held Remot...