Page 6 of 13
MW38-BV Modular Fireplace
XG0310 Rev. 01 - 11/98
Installation
Wiring
Figure 8b.
Wiring schematic for optional fan kit.
Figure 8a.
Wiring for optional air circulating fan kit.
G
L1-WH
L2-BLK
Quick Connect
plug to motor
Installing the Log Set
The
MW38-BV
is supplied with four (4) soft fibre logs. Logs
"A"
and
"B"
are permanently attached to a fibre base, which is pre-installed by
the factory. To install the two small logs
("C"
and
"D"
), simply place
them onto their mating positions as shown in figure 9a below
.
When
log set is installed it should look like figure 9b.
Figure 9a.
Log placement.
Figure 9b.
Completed log installation.
Log 'C'
Logs 'A' and 'B'
Log 'D'
NOTES
:
If logs are not placed properly, excessive sooting will result.
If handling or vacuuming the logs, do not attempt to move
the two large logs. They are extremely fragile, and will break
easily.
The surface of the logs will crack due to the heat from the
flames. This is a normal occurance.
Gas Control and Pilot Wiring
MW38-BV-I
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 7.
Wiring for the MW38-BV-I with Honeywell gas control and
pilot.
Wiring for the
optional
Fan Kit
All 38 Series Modular fireplaces may be equipped with optional fan or
blower kits for circulating heat into the living space.
Installations in Canada
which employ the fans must be electrically
grounded in accordance with
CSA C22.1
Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA
which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code,
ANSI/NFPA 70-1987.
For more information see the
Fan Kit Installation Guide
included
with the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
115/1/60 Supply
G
L1 L2