H34D Gas Fireplace

Part No. XG0130

The Warranty

The Warranty

The Warranty

The Warranty

The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-
year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs.
Glass, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.

This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.

If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation outlined
below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, and will also pay
for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies will, at its option, refund
the purchase price of the Montigo Gas Appliance.

This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which are not
manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All replacement or repair
components will be shipped F.O.B. the nearest The Companies factory.

Qualifications To The Warranty

Qualifications To The Warranty

Qualifications To The Warranty

Qualifications To The Warranty

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:

(1)

The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo Gas Appliance
covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas Appliance could create
serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building codes. This warranty
does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies

(2)

The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such as wood,
coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

Limitations On Liability

Limitations On Liability

Limitations On Liability

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, expressed
or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.

In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs or is discovered
before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty with respect to this Montigo Gas Appliance
is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

Investigation Of Claims Against Warranty

Investigation Of Claims Against Warranty

Investigation Of Claims Against Warranty

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.

The Companies Are Not Responsible For Work Done Without Written Consent

The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.

Dealers Have No Authority To Alter This Warranty

The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How T

How T

How T

How T

How To Register A Claim Against W

o Register A Claim Against W

o Register A Claim Against W

o Register A Claim Against W

o Register A Claim Against Warranty

arranty

arranty

arranty

arranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably possible
after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

Other Rights

Other Rights

Other Rights

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without
notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Warranty

Содержание H34D

Страница 1: ...ur gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier For Your Safety Do n...

Страница 2: ...ConsultyourlocalGasInspectionBranchoninstallationrequirementsfor factory builtgasfireplaces Installation repairsshouldbedonebya qualifiedcontractor Installations in Canada must conform to the current CAN CGA B 149 1and 2GasInstallationCodeandlocalregulations Iftheoptional air circulatingfankitisinstalled itmustbeelectricallygroundedin accordance with CSA C22 1 Canadian Electrical Code Part 1 and o...

Страница 3: ...m Corner framing dimensions using a 45 elbow Figure 2 Framing dimensions When sheetrock is not used behind the fireplace framing depth may be reduced to 16 Framing WARNING When this appliance is installed directly on carpeting tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extending the full width and depth of the appliance Top View Front Vi...

Страница 4: ...cegasconnectionand themainoperatinggasvalveislocatedbehindtheremovabletrimatthe bottomoftheunitandneedonlybeattachedtothegasline withan approved fitting as required by the applicable installation codes Only use gas shut off valves approved for use by the state province region or governing body in which the appliance is being installed or asrequiredbytheapplicableinstallationcodes Flexiblegasconnec...

Страница 5: ...SRframeasshownhere and attachbyscrewingthroughthefourpilotholesinthetermination MSR MTO 3 MTO 3F MTO 3 MTKOG 1 Ensurethatthetwolongmountingbracketsarefacingthebottomof thetermination Seeinset Thiswillprovidemoreheatprotection atthetopofthetermination wheretemperaturesarehighest 2 Attachtothefaceplateoftheterminationusingfoursheetmetalscrews Installing Heat Guards over Terminations Installation Ins...

Страница 6: ...let using5screws asillustratedbelow Figure 7a Flue cap installation for Top Vented fireplace Figure 7b Flue collar installation for Top Vented fireplace Figure 8a Flue cap installation for Rear Vented fireplace Figure 8b Flue collar installation for Rear Vented fireplace H34DL Rear Vent UsethefollowinginstructionstoconvertanH34DLforTopVentuse 1 Installthe4 innerfluecaponthetopflueoutletandsecureth...

Страница 7: ...gcanaffectthefireplace s combustion themaximumverticalventrunforaTopVentedunitis32feet The Venting Graph Measuretheverticalheightfromthefireplacehearthtothecentreofthe terminationandthehorizontalrunfromthefromthefireplacefluecollarto thewallflangeofthetermination PlotontheVentingGraph Fig 9 with an X If the X falls on or above the top boundary of the shaded area the installationisacceptable Exampl...

Страница 8: ... D rigidsectionsmaybeusedinconjunctionwith oneanothertoobtaindifferentpossiblehorizontallengthinstallations Figure 13 ExtendedInstallationusingacombinationofsolidandflex venting Use the vent graph to determine your allowable run then select appropriate components Figure 14 RetractedInstallationusingacombinationofsolidandflex venting Use the vent graph to determine your allowable run then select ap...

Страница 9: ...h MEXT 2 24 length MEXT 3 36 length MEXT 4 48 length D Support Ring Plate MSPXT 7 E Firestop FS 7 F Roof Flashing MRF 7 1 12 7 12 pt MRF 12 7 12 12 12 pt Figure 16 Straight vertical venting showing required MXT 10 adaptor supplied with the MVTK 1 termination A maximum of two offsets each offset has two 90 bends may be madeandshallnotexceedtotallengthof25 oftheverticalventheight when measured cente...

Страница 10: ...andattachittotheEEL 45 Slidethefireplaceinto positionandattachtothetermination EnsurethattheRHS101 heat sheild is installed before attaching the pipe to the termination 3 Corner Installation 45 or less Use an MTO 3 termination and an MFL 1 or MFL 2 12 or 24 compressedlength andaframe ifappropriate Flexmaybeturned toobtaindesireddegreeofanglerequiredbutmustnotexceed45 Ensure that the RHS101 heat sh...

Страница 11: ...ceptable Installation Iftheverticaldimensionfromthehearthis94 andthehorizontal runtothewallflangeoftheventterminationis126 thiswouldbe anacceptableinstallation Example C Unacceptable Installation Iftheverticaldimensionfromthefloorofthefireplaceis78 andthe horizontalruntothewallflangeoftheventterminationis108 this would NOT be an acceptable installation Figure 22 H34D Rear Vent Venting Graph Instal...

Страница 12: ...tocombustiblematerials Newtechnology tomeetconsumerandgovernmentdemandsforthe wiseuseofenergy haspromptedustomanufacturemanymodelsof fireplaceswhicharehot fuelandenergyefficient Pleasebeaware temperaturesoverthemantelwillriseabovenormal roomtemperatureandwallsabovefireplacemaybehottotouch Werecommendcarefulconsiderationbegiventotheeffectsofelevated manteltemperatureswhichmaybeinexcessofproductdesi...

Страница 13: ...NOTE If any of the original wire supplied with the appliance is replaced it must be replaced with the same type or its equivalent Figure 26b Wiring schematic for optional fans Figure 26a Wiring for optional fans Removing and Installing the Door Removing the door The door is held in place by a lip on the top of the metal frame and two bucklesatthebottom Releasethebucklesandliftthedoorcarefullyup an...

Страница 14: ...Base log placement Figure 28d Bottom left and right log placement Figure 28e Top left and right log placement Base Log Bottom Left Log Bottom Right Log Top Left Log Top Right Log Base Log Bottom Right Log Bottom Left Log Top Left Log Top Right Log 5 Start the fireplace If the flame appears satisfactory replace the glass door If the flame does not appear satisfactory double check the air inlet and ...

Страница 15: ...odel H34D 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then smell ga...

Страница 16: ... light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower trim 3 Turn the switch on the gas control to Off 4 Flip up the trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Turn sw...

Страница 17: ...ped with an adjustable burner allowing you to raise orlowertheflames Toadjusttheflames locatetheblackknobmarked Hi Lo in the centre of the gas control valve See Figure 29 The front burnersarenotadjustable Toraisetheflameheight turntheblackknob locatedbehindthe lower trim counterclockwise Tolowertheflameheight turnclockwise Figure 29 Hi Lo Adjustment on the H34D s gas valve Cleaning Whenthefireplac...

Страница 18: ... yourlocaldealerorthemanufacturer HONEYWELL SV 9500 SV9600 Troubleshooting Sequence NOTE Before Troubleshooting Familiarize Yourself With The Startup And Checkout Procedure Turn Gas Supply off Set thermostat to call for heat SV9500 SV9600 is powered 24 VAC nominal NO NO NO NO NO YES YES YES YES YES YES YES NO NO NO START Igniter warms up and glows red Pilot Valve opens Turn gas on Pilot Burner lig...

Страница 19: ...ltinafirehazard Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability ItisexpresslyagreedandunderstoodthatTheCompaniessoleobligation andpurchaser sexclusiveremedyunderthisWarranty underanyotherwarranty expressed orimplied orincontract tortorotherwise shallbelimitedtoreplacement repair orrefund asspecifiedabove InnoeventshallThe...

Страница 20: ...ted States 6 feet 1 8 m minimum in Canada L clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearanceunderveranda po...

Страница 21: ...he H34D I equipped with Hot Surface Ignition HSI are not approved for use in mobile or manufac tured homes The H34D MH is rated for NaturalGasat18 000BTU H 5 28Kilowatts max input and 14 000BTU H 4 10Kilowatts min input Propane at 18 000 BTU H 5 28 Kilowatts max input and 14 000 BTU H 4 10Kilowatts min input Conversion Kits TheH34D MHmobilehomeapplianceisfieldconvertiblebetween Natural Gas NG and ...

Страница 22: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0130 Rev 0 11 2003 ...

Отзывы: