Page 12
H34D Gas Fireplace
Part No. XG0130
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the top
and on the front of the fireplace provided that they do not project beyond
shaded area shown in Figure 23. Side wall clearances are 3". Combus-
tible surrounds may be installed with 3" clearance to the side of the
fireplace as shown in Figure 24.
Fireplace Facing
When selecting the finish material for your fireplace, it is important to
remember the following: THE LOWER GAS CONTROL PANEL MUST
NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air
supply for the control compartments and heat exchanger it also
prevents access for servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the fireplace opening at all, because it will interfere with the
access to retainers for removal of glass door.
Installation
Figure 23.
Combustible mantles and facings.
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements are
for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures. This can cause melting, deforma-
tion, discoloration or premature failure of T.V. and radio components.
Painting:
Special care is recommended by the Master Painters and Decorators
Association, when painting the fireplace surrounds, to select and apply a
quality Alkyd sealer prior to the applying of latex paints. This is to
prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.
Figure 24.
Combustible surrounds.
Wiring
Gas Control and Pilot Wiring
H34D-I
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 25.
Wiring for the H34D-I with Honeywell gas control and pilot.