24
Installation
xg0227 - 112718
POD - Pilot on Demand
What is POD and CPI mode?
This fireplace is equipped with an “On Demand” intermittent pilot
ignition system (IPI) which also includes a continuous pilot ignition
(cPI) mode with an integrated seven day timer.
In IPI mode, the pilot will light before the main burner, when the appliance
is turned on using a wall switch, remote or from a thermostat. once the
appliance is turned off, the main burner and pilot flame will shut down.
the continuous (cPI) mode exists to ease the startup phase in colder
climates by keeping the firebox and venting warm when the main burner
is not in use. The timer automatically switches off the pilot when the
appliance has not been used for seven days.
when the cPI function is turned on, the pilot will remain on after
the fireplace is turned off. A timer will then begin the countdown for
approximately seven (7) days before shutting off the pilot if the appliance
is not used. this countdown will reset anytime the burner is use.
If your appliance is equipped with a remote control device capable of
selecting IPI / CPI modes, refer to remote operating instructions.
In order to start your pilot, turning the main burner on with the
switch, remote or thermostat and then turning it off will reactivate the
continuous pilot mode and reset the seven day timer.
A jumper is supplied with this unit that can be plugged into the wire
harness connected to the controller. this jumper cable gives the
Remote Control the ability to operate the POD / IPI switch and set the
unit to operate in either condition. Please refer to jumper installation
instructions for more information.
Installing the CPI Jumper Cable
1).
Access the control box.
2).
Remove the bag containing the Jumper cable from the wire
harness connected to the controller.
3).
Find the corresponding plug attached to the control wire harness
and connect the cPI jumper.
4).
see operation section to turn remote into cPI mode.
figure 19.a
Open the control box drawer
figure 19.b
Locate Jumper cable
figure 19.c
Connect CPI
Remote Continuous Pilot (CPI)
Selection
Requires installation of the CPI JUMPER
with the system in "off" position press the Mode Key, to index to
the cPI mode icon, Pressing the up Arrow Key will activate the
continuous Pilot Ignition mode (cPI). Pressing the down Arrow
Key will return to IPI. A single "beep" will confirm the reception of
the command.