B-Series DV-2 Gas Fireplace
Page 15
Part No. XG0160 - 151125
Installation
Wiring
Wiring for the
optional
Fan Kit
All
B-Series DV-2
fireplaces may be equipped with optional fan
kits for circulating heat into the living space.
Installations in Canada
which employ the fans must be
electrically grounded in accordance with
CSA C22.1
Canadian
Electrical Code Part 1 and/or Local Codes.
Installations in the USA
which employ the fans must be
grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70-1987.
For more information see the
Fan Kit Installation Guide
included with the fan kit.
115/1/60 Supply
G
L1 L2
G
L2-WH
L1-BLK
Quick Connect
plug to motor
NOTE:
If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
Figure 25.
Wiring schematic for optional fans.
Figure 24.
Wiring Diagram for the
SIT Proflame 2
Electronic Ignition
1.5V AA type
1.5V AA type
1.5V AA type
1.5V AA type
BLACK
WHITE
GREEN
To PPO
SPARK
SENSOR
RED
BLACK
BATTERY
PACK
TO ON/OFF
WALL SWITCH
YELLOW/GREEN
ORANGE
GREEN
6
10
4
6
3
4
OPTIONAL CPI/IPI SWITCH
BLUE
WHITE
X1
X5
X4
X3
X2
LED Lights
LED1 - Red LED
LED2 Amber LED
3.15A FUSE
SW1
WHITE
BLACK
OPTIONAL