1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.Check to make sure the dip switches from the transmitter and receiver are set on the

same frequency.

CAUTION:  Make sure main power is turned off.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing

and canopy.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.  

DO NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction

box and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance

from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is

positioned for measurement. Repeat for each blade. If all blade levels are not equal, you

can adjust blade levels by the following procedure. To adjust a blade tip down, insert a

washer (not supplied) between the blade and blade holder at the screw closest to the

motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade

holder at the two screws farthest from the motor.  Reverse the position of the washer if

blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can

redistribute the weight and possibly result in smoother operation.

1.Check wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before enterin switch housing and

canopy.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not

work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation,

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any

faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing

difficulty in installation, please call our Customer Service Center at the number printed on your parts list

insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service

disconnecting means to prevent power from being switched on accidentally.  When the service

disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a

tag, to the service panel.

Trouble

Suggested Remedy

Содержание 5RDR Series

Страница 1: ... to this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5RDR Series Fan Total fan weight UL Model No AC 212 003 27 75 kgs 61 05 lbs ...

Страница 2: ...l Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning ...

Страница 3: ...ve the 6 screws attaching the Mounting neck from the mounting plate Retain the 6 screws for re as sembly 3 Secure mounting plate directly to a joist from the buliding structure Use only the appropriate wood screws and washers included with your fan Caution Wood screws must go through into the building joist Note If Installing It In The U S Do Not Re move Knockouts In The Outlet Box 5 Outlet box Mo...

Страница 4: ...to hold downrod securely in the arch yoke 15 Place downrod into the arch yoke and align the slot in arch yoke and the hole in the downrod 13 Place arms over the fan housing Make sure the arms with electrical connection plugs are next to the plugs on the fan housing 16 Remove pin from downrod and save for later step 14 Push the yoke cover onto downrod Thread lead wires and safety cable through the ...

Страница 5: ...pedo shape bulbs 24 23 Tighen all 6 screws for arch arms se curely 20 Install arch mount by using clips in plastic bag Place clip through tab and fasten securely 19 Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers th...

Страница 6: ...ole slots with the screws on the bottom of the Mounting bracket Rotate the canopy Counter Clockwise to lock in place Tighten the screws to secure the Canopy See inset for Keyhole shape 33 Attach blade brackets to blades using the blade bracket screws and wash ers provided 34 Install all 5 fan blade assemblies to the motor as shown above Tighten screws securely 35 Make wire connections to power sou...

Страница 7: ...ady A23 GP 23A all 12V Attach cover of remote by plac ing over buttons and snap the battery cover in place Place face plate over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snaping into place 40 39 HAND HELD INSTALL Install wall control unit to outlet box using machine screws provided 41 Attach front cover to wall contro...

Страница 8: ...ight will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fan must be running to reverse UPLIGHT ON OFF SE...

Страница 9: ...positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse ...

Страница 10: ...Mar 2012 New format May 2013 Update for CUL regulation ...

Отзывы: