WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA
70-1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be
turned upward and pushed carefully up into the outlet box.

WARNING

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.

WARNING

: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

31.8 kg (70 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION: 

For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Re-

move Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to
the building structure (or the ceiling joist).

WARNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do

not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING

: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. UC7067RC manufac-

tured by Rhine Electronic Co., Ltd.

WARNING: 

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed

control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION

: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,

Stepladder and Wire Strippers.

Содержание 5RDR Series

Страница 1: ... to this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5RDR Series Fan Total fan weight UL Model No AC 212 003 27 75 kgs 61 05 lbs ...

Страница 2: ...l Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning ...

Страница 3: ...ve the 6 screws attaching the Mounting neck from the mounting plate Retain the 6 screws for re as sembly 3 Secure mounting plate directly to a joist from the buliding structure Use only the appropriate wood screws and washers included with your fan Caution Wood screws must go through into the building joist Note If Installing It In The U S Do Not Re move Knockouts In The Outlet Box 5 Outlet box Mo...

Страница 4: ...to hold downrod securely in the arch yoke 15 Place downrod into the arch yoke and align the slot in arch yoke and the hole in the downrod 13 Place arms over the fan housing Make sure the arms with electrical connection plugs are next to the plugs on the fan housing 16 Remove pin from downrod and save for later step 14 Push the yoke cover onto downrod Thread lead wires and safety cable through the ...

Страница 5: ...pedo shape bulbs 24 23 Tighen all 6 screws for arch arms se curely 20 Install arch mount by using clips in plastic bag Place clip through tab and fasten securely 19 Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers th...

Страница 6: ...ole slots with the screws on the bottom of the Mounting bracket Rotate the canopy Counter Clockwise to lock in place Tighten the screws to secure the Canopy See inset for Keyhole shape 33 Attach blade brackets to blades using the blade bracket screws and wash ers provided 34 Install all 5 fan blade assemblies to the motor as shown above Tighten screws securely 35 Make wire connections to power sou...

Страница 7: ...ady A23 GP 23A all 12V Attach cover of remote by plac ing over buttons and snap the battery cover in place Place face plate over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snaping into place 40 39 HAND HELD INSTALL Install wall control unit to outlet box using machine screws provided 41 Attach front cover to wall contro...

Страница 8: ...ight will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fan must be running to reverse UPLIGHT ON OFF SE...

Страница 9: ...positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse ...

Страница 10: ...Mar 2012 New format May 2013 Update for CUL regulation ...