Cautions and Warnings

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70), including 

fire-rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
After making

 

the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side 

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed 

carefully up into the outlet box.

WARNING:

 Before you begin installing, servicing or cleaning the fan unit, switch the power off at the service panel and lock the service panel to prevent 

the power from being switched back on accidentally. If the service panel cannot be locked to prevent the power from being switched on accidentally, 

securely fasten a warning sign to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor 

to the trailing edge of the blade.

WARNING:

 To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or 

less” and use mounting screws provided with the outlet box.

CAUTION

: Comply with local codes and regulations. If installing the secondary support safety cable in the U.S., do not remove knockouts in the outlet 

box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure or the ceiling joist.

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert 

foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. UC9031 manufactured by Rhine 

Electronic Co., Ltd. 

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment 

manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing the light kit.

CAUTION:

 The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the 

product should be returned to an authorized service facility for examination or repair.  
All set screws must be checked and tightened where necessary before installation.

Note

: Suitable for use in damp locations. Install the fan under covered or enclosed patios or porches.  

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, FOLLOW THESE INSTRUCTIONS.

Содержание 3ERAR52 D Series

Страница 1: ...NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3ERAR52XXXD Series Fan CUL Model N...

Страница 2: ...nockouts in the outlet box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of...

Страница 3: ...acket onto the outlet box Partially loosen the two screws on the outlet box attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration Have the moun...

Страница 4: ...ans installed in Canada and for USA fan and light kit combinations over 35lbs Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on...

Страница 5: ...ve 1 preassembled screw from light pan Save screw for later use Connect white wire from fan to white wire from light fixture and then connect blue or black wire from fan to black or blue wire from lig...

Страница 6: ...t clockwise until tight Setting the reverse switch on the left hand side will result in downward airflow and setting the switch on the right hand side will result in upward airflow Note Reverse switch...

Страница 7: ...ad wires from fan Connect the black white wire marked AC IN L from wall controller to the HOT wire from house and then connect the black wire marked TO MOTOR L of wall controller to the fan lead wire...

Страница 8: ...unting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this...

Страница 9: ...Mar 2022...