Design Guide - Flush Installation
CUSTOM HANDLE DESIGN GUIDE
Custom handles must be used for flush installation. For
custom handle installation, counterbore holes in rear of
decorative panels must ensure 1/2” material thickness
remains for handle support.
NOTE: The counterbore must not exceed 1” in diameter.
Minimum distance on Fresh Food
Doors from handle side edge to
handle center should be 1-1/4" on
each door as shown.
Minimum distance on Freezer Door
from top edge to handle center on
the freezer drawer should be 1-1/2”
as shown.
1/4”
1/2”
3/4”
7/8"
0.85"
1/2"
1-1/4”
1-1/4”
1-1/2”
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The cutout depth must be 26-3/16”
The refrigerator will project forward, slightly beyond
adjacent cabinetry, depending on your installation.
Allow minimum 1/8” air gap between case back & wall.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed
the 24
”
installation depth shown. The top case trim
overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor
or back wall. Route GE SmartConnect
™
kit or 1/4
”
O.D.
copper tubing between the cold water line and the
water connection location. The tubing should be
long enough to extend to the front of the refrigerator.
Installation of an easily accessible shut-off valve in the
water line is required.
DIMENSIONS AND CLEARANCES
Product Clearances
These refrigerators are equipped with a 3-position door
stop. The factory set 115° door swing can be adjusted to
90° if clearance to adjacent cabinets or walls is restricted.
23-7/8"
Behind
Frame
90°
90°
19-1/2”
4” Min. Distance
to Adjacent Wall
from Cutout
8"
Min. to
Wall
8"
Min. to
Wall
115°
115°
Do not use the 130° door swing option for flush
installation.
For a 90° door swing, allow 4
”
min. clearance to
adjacent wall from cutout. If the 90° door stop position
is used, pan access is maintained, but pan removal is
restricted.
* Shipping height. The
refrigerator can be
adjusted to fit into a
cutout that is 85
”
max.
height. Use leveling
legs and wheels for a
maximum 1
”
height
adjustment.
6"
Wall View
Electrical
Area
85"
Finished
Opening
75-1/2" From
Floor to Bottom
of Electrical Area
10"
26-3/16" Cutout
Depth
39"
Finished Width
4-1/16"
7"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
7"
3-1/2"
Water Supply
36" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83 1/2"
at
Rear
25-3/8"
Case Depth
Depth Including
Handles:
27-1/2"