9.0 MAINTENANCE
ISOLATE DIVIDER FROM MAINS SUPPLY BEFORE ATTEMPTING ANY
MAINTENANCE OPERATIONS.
MAINTENANCE SHOULD ONLY BE CARRIED OUT BY FULLY TRAINED PERSONNEL
Due to the low maintenance design of the divider, maintenance consists of the operations
in the cleaning section and a few of the following checks:
Conveyor belt adjustment (as required).
Condition and greasing (check monthly)
Weight adjuster chain condition and greasing (check monthly)
Conveyor Belt Adjustment
Conveyor belt should be no tighter than necessary to eliminate slippage.
Over tensioning can lead to belt and/or bearing failure. The belt should be adjusted by
means of the adjustment tensioning nuts.
The belt should run with equal clearance between its edges and the conveyor unit side
frames. If one edge of the belt is tighter than the other, it will tend to run towards the
slack side. This tracking defect can be eliminated by individual adjustment of the
tensioning nuts.
Caution
Adjustment nuts should not be continually tightened (this will cause bearing failure or
the moulding belt to stretch and break). It may be that one side is too tight so should
be eased off a little.
ADJUSTMENT NUTS
(each side)
Содержание fusion compact
Страница 4: ...FUSION Compact Bread Plant Rev A21 14 04 21 4 ...
Страница 9: ...FUSION Compact Bread Plant Rev A21 14 04 21 9 BREADPLANT ASSEMBLED SECTION 1 ...
Страница 35: ...FUSION Compact Bread Plant Rev A21 14 04 21 35 THIS INFORMATION IS NOT AVAILABLE AT THE MOMENT ...
Страница 56: ...FUSION Compact Bread Plant Rev A21 14 04 21 56 THE FOLLOWING SHOULD ONLY BE USED BY TRAINED SERVICE ENGINEERS ...
Страница 57: ...FUSION Compact Bread Plant Rev A21 14 04 21 57 ...
Страница 58: ...FUSION Compact Bread Plant Rev A21 14 04 21 58 ...
Страница 59: ...FUSION Compact Bread Plant Rev A21 14 04 21 59 ...
Страница 60: ...FUSION Compact Bread Plant Rev A21 14 04 21 60 ...
Страница 61: ...FUSION Compact Bread Plant Rev A21 14 04 21 61 YASKAWA INVERTER DEFAULT SETTINGS ...
Страница 64: ...FUSION Compact Bread Plant Rev A21 14 04 21 64 ELECTRICAL DISTRIBUTION ...
Страница 65: ...FUSION Compact Bread Plant Rev A21 14 04 21 65 CONTROL CIRCUIT ...
Страница 84: ...FUSION Compact Bread Plant Rev A21 14 04 21 84 ...
Страница 85: ...FUSION Compact Bread Plant Rev A21 14 04 21 85 11 0 ELECTRICAL INFORMATION ...
Страница 86: ...FUSION Compact Bread Plant Rev A21 14 04 21 86 ...
Страница 87: ...FUSION Compact Bread Plant Rev A21 14 04 21 87 ...