To Turn Off Gas To Heater
1. Turn the On/Off switch to Off position or set the thermostat
to lowest setting. (R models only)
2. Turn off all electric power to the fireplace if service is to
be performed.
A. This heater has a pilot which must be lit manually. When
lighting the pilot follow these instructions exactly.
B. BEFORE LIGHTING smell all around the heater area for
gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any fireplace
• Do not touch any electric switch
• Do not use any phone in your building
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the Fire
Department
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, do not try to repair it, call a qualified service
technician. Applying force or any attempted repair may
result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician
to inspect the heater and to replace any part of the
control system and any gas control which has been
under water.
If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
WARNING
!
Lighting Instructions
1.
STOP!
Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. Turn the On/Off switch to “OFF” position or set thermostat
to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise
to “OFF”.
PIL
OT
ON
OFF
ON
PILOT
O
FF
OFF
FP1067
lighting instruction
knobs
3/9/01 djt
5
4
3
2
1
O
FF
P
ilo
t
SIT NOVA
3/8" - 1/2"
FP1068
Lighting instructions
Pilots
• If knob does not pop up when released, stop and
immediately call your service technician or gas supplier.
• If after several tries, the pilot will not stay lit, turn the gas
control knob to “OFF” and call your service technician or
gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. Turn the On/Off switch to “ON” position or set thermostat
to desired setting.
14. Turn on all electrical power to the fireplace.
10. Push the control knob all the way in and hold. Immediately
light the pilot by repeatedly depressing the piezo spark
ignitor until a flame appears. Continue to hold the control
knob in for about one (1) minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain lit. If it
goes out, repeat steps 5 through 8.
6. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow “B” in the safety information above. If you do not
smell gas, go to the next step.
7. Remove glass door before lighting pilot. (See Glass Frame
Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counter-clockwise
to
“PILOT”.
3. Open control access panel.
4. Push in gas control knob slightly and turn clockwise
to “OFF”. Do not force.
5. Close control access panel.
E. Lighting & Operating Instructions
FOR YOUR SAFETY READ BEFORE LIGHTING