A. Unpack the Stove
Remove the unit from the skid by loosening the bolts located
in the shipping brackets. Once bolts are removed, remove
shipping brackets from around the leg levelers.
B. Install Optional Fan Kit
1. Remove shroud assembly by loosening two (2) hex head
bolts on lower inside of shroud. Lift shroud assembly up
and away from stove.
2. Attach the fan to the rear shroud by engaging the upper
flange of the fan skirt under the lower edge of the shroud
and secure the skirt with the four screws and one star
washer provided. (Figs. 2 & 3)
FK104
Install cover plate
Rheostat
Retaining Nut
Control Knob
Figure 5
- Attach rheostat to bracket.
MOTOR
SNAPST AT
ON/OFF
RHEOST AT
WHT
WHT
BLK
BLK
BLK
GRN
BLK
ST236
FK26 wiring diagram
12/99
Figure 6
- Fan wiring diagram.
ST344a
pinnacle
install fan
2/4/00
Upper
Flange
Figure 2
- Place upper flange behind lower edge of shroud.
Figure 3
- Correct position of fan skirt installation.
ST345a
pinnacle
fan in place
12/18/03
Figure 4
- Attach snapstat to inner shroud.
ST346a
install FK28
snapstat
12/18/03
Porcelain enameled surfaces are fragile. Handle porcelain
enameled castings tenderly. Familiarize yourself with
the assembly steps before you begin and proceed
with deliberation and care. If possible, have assistance
available.
Place enameled castings on a soft, cushioned surface
until you are ready to assembly.
Avoid contact between the castings and other hard
surfaces or objects.
CAUTION
!
3. Feed the snapstat wire lead up between the inner and outer
rear shroud panels and secure the snapstat to the upper
right side of the inner shroud. (Figure 4)
4. Secure the snapstat wire harness to the shroud panel
using the wire tie provided.
5. Replace shroud and tighten the two (2) hex head nuts on
lower inside of shroud.
6. Route the rheostat control switch and wire forward under
the stove. Use the wire tie to secure the fan and rheostat
wire harnesses together to the tubing under the bottom
heat shield.
7. Install the rheostat onto the bracket to the left of the valve.
(Figure 5)
Failure to position the parts in accordance with these
diagrams, or failure to use only parts specifically
approved with this heater may result in property damage
or personal injury.
WARNING
!
2
Assembly