background image

8

3-90-733069

Monessen • Sundance VF Installation Manual_R1 • 04/17

A. Unpack the Stove

Remove the unit from the skid by loosening the bolts located 

in the shipping brackets. Once bolts are removed, remove 

shipping brackets from around the leg levelers.

B. Install Optional Fan Kit

1.  Remove shroud assembly by loosening two (2) hex head 

bolts on lower inside of shroud. Lift shroud assembly up 

and away from stove.

2.  Attach the fan to the rear shroud by engaging the upper 

flange of the fan skirt under the lower edge of the shroud 

and secure the skirt with the four screws and one star 

washer provided. (Figs. 2 & 3)

FK104

Install cover plate

Rheostat

Retaining Nut

Control Knob

Figure 5

 - Attach rheostat to bracket. 

MOTOR

SNAPST AT

ON/OFF

RHEOST AT

WHT

WHT

BLK

BLK

BLK

GRN

BLK

ST236

FK26 wiring diagram

12/99

Figure 6

 - Fan wiring diagram.

ST344a

pinnacle

install fan

2/4/00

Upper 

Flange

Figure 2

 - Place upper flange behind lower edge of shroud.

Figure 3

 - Correct position of fan skirt installation.

ST345a

pinnacle

fan in place

12/18/03

Figure 4

 - Attach snapstat to inner shroud.

ST346a

install FK28

snapstat

12/18/03

Porcelain enameled surfaces are fragile. Handle porcelain 

enameled  castings  tenderly.  Familiarize  yourself  with 

the  assembly  steps  before  you  begin  and  proceed 

with deliberation and care. If possible, have assistance 

available.
Place  enameled  castings  on  a  soft,  cushioned  surface 

until you are ready to assembly.
Avoid  contact  between  the  castings  and  other  hard 

surfaces or objects.

CAUTION

!

3.  Feed the snapstat wire lead up between the inner and outer 

rear shroud panels and secure the snapstat to the upper 

right side of the inner shroud. (Figure 4)

4.  Secure  the  snapstat  wire  harness  to  the  shroud  panel 

using the wire tie provided.

5.  Replace shroud and tighten the two (2) hex head nuts on 

lower inside of shroud.

6.  Route the rheostat control switch and wire forward under 

the stove. Use the wire tie to secure the fan and rheostat 

wire harnesses together to the tubing under the bottom 

heat shield.

7.  Install the rheostat onto the bracket to the left of the valve. 

(Figure 5) 

Failure  to  position  the  parts  in  accordance  with  these 

diagrams,  or  failure  to  use  only  parts  specifically 

approved with this heater may result in property damage 

or personal injury.

WARNING

!

Assembly 

Содержание SD30NV

Страница 1: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier T...

Страница 2: ...information 1 Safety Operations A Important Safety Information 3 B Stove Dimensions 4 C Clearance to Combustibles 5 D Floor Protection 5 E Gas Specifications 6 F Gas Inlet Manifold Pressures 6 G High...

Страница 3: ...re rating A Important Safety Information In order to ensure safe and effective installation this unit must be installed only by a qualified agency individual firm corporation or company that is experi...

Страница 4: ...Manual_R1 04 17 B Stove Dimensions Figure 1 Sundance freestanding shell dimensions Freestanding Stove Drawing Not to Scale C L C L 5004 UVS27 Freestanding specs 1 02 9 229 mm 26 680 mm 3 76 mm Valve...

Страница 5: ...1 2 191mm V 20 508mm E 5 3 4 146mm W 15 381mm F 4 102mm X 10 254mm G 2 1 4 57mm Y 5 127mm H 1 25mm Z 2 51mm FP599a stove mantel heights 9 27 99 djt S T U V W X Y Z A B C D E F G H A Ceiling 35 889mm B...

Страница 6: ...bs H Odor During Operation Neither natural gas nor propane gas give off an odor when burned The nature of a vent free combustion system however is such that odors may occasionally be produced during h...

Страница 7: ...t are highly energy efficient and that allow little heat loss Your home needs to breathe however and all fuel burning applianceswithinitrequirefreshairinordertofunctionproperly andsafely Exhaustfans c...

Страница 8: ...h snapstat to inner shroud ST346a install FK28 snapstat 12 18 03 Porcelain enameled surfaces are fragile Handle porcelain enameled castings tenderly Familiarize yourself with the assembly steps before...

Страница 9: ...TH C Install ON OFF Switch The switch assembly parts are found in the parts bag 1 Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud Figure 7 2 Run...

Страница 10: ...the valve side and 1 2 propane gas supply line with an input of 28 000 Btus at a maximum manifold pressure of 10 0 and minimum inlet supply for adjustment of 11 0 w c Gas connection should be made in...

Страница 11: ...er the bent tab on the right When the log is in place it rests on the tab mentioned earlier and the tip of it comes in contact with the branch on the rear log Figure 10 4 Install the left log by placi...

Страница 12: ...rrect Follow regular maintenance procedures as described in the Maintenance section of this manual ST673 RUVSOD Pilot assembly location 7 249 01 djt Natural Pilot LP Pilot Figure 14 Pilot assembly loc...

Страница 13: ...ty information above 2 Turn off all electrical power to the fireplace 3 Turn the On Off switch to OFF position or set thermostat to lowest level 4 Open control access panel 5 Push in gas control knob...

Страница 14: ...parks but Pilot does not light A Gas supply is turned off or supply line shut off valve is closed Turn on gas supply or open supply line shut off valve B Control Knob is not in PILOT position Turn Con...

Страница 15: ...al gas service technician Pilot lights but Main Burner does not A Gas supply line shut off valve is not fully open Fully open gas supply line shut off valve B Foreign material is blocking Burner ports...

Страница 16: ...A DAMAGED OR LOOSE LOG SET Use a soft bristled brush vacuum cleaner attachment to remove dust or debris from the log set pilot and burner Use care as the log set is fragile 5 Inspect the catalytic com...

Страница 17: ...6a b c d 9 10 14a b 17 1d 23 24 25 26 27 5057 Stardance VF parts Hearth Home Technologies reserves the right to make changes in design materials specifications prices and discontinue colors and produc...

Страница 18: ...80 27 Right End Black 30001279 28 1 4 Fiberglass Gasket not shown 1203560 29 Magnet Door not shown 30004112 30 Magnet Control Door not shown 1408818 Flexline Black 20H1011 Optional Accessories Availab...

Страница 19: ...In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distri...

Страница 20: ...WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface fini...

Страница 21: ...21 3 90 733069 Monessen Sundance VF Installation Manual_R1 04 17...

Страница 22: ...352 Mountain House Road Halifax PA 17032 22 3 90 733069 Monessen Sundance VF Installation Manual_R1 04 17...

Отзывы: