ODGR Series Outdoor Gas Fireplace

92D0001

General Information

This gas appliance should be installed by a qualified 
installer in accordance with local building codes and with 
current 

CSA-B149.1

 Installation codes for Gas Burning 

Appliances and Equipment.
FOR U.S.A Installations follow local codes and/or the cur-
rent 

National Fuel Gas Code. ANSI Z223.1/NFPA 54

.

In the Commonwealth of Massachusetts, all gas fittings 
and installation of this heater shall only be done by a 
licensed gas fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION PLEASE 
NOTE THE FOLLOWING:

1.  This appliance gives off high temperatures and should be 

located out of high traffic areas and away from furniture.

2.  Children and adults should be alerted to the hazards of the 

high surface temperatures of this appliance and should stay 
away to avoid burns or ignition of clothing.

3.  Children should be carefully supervised when they are in the 

same room as your appliance.

4.  Under no circumstances should this appliance be modified. 

Parts having to be removed for servicing should be replaced 
prior to operating this appliance again.

5.  Installation and any repairs to this appliance should be car-

ried out by a qualified service person. A professional service 
person should be contacted to inspect this appliance an-
nually. Make it a practice to have all of your gas appliances 
checked annually.  More frequent cleaning may be required 
due to excess lint and dust from carpeting, bedding material, 
etc.

6.  Control compartments, burners and air passages in this ap-

pliance should be kept clean and free of dust and lint. Make 
sure that the gas valve and pilot light are turned off before 
you attempt to clean this unit.

7.  Keep the area around your appliance clear of combustible 

materials, gasoline and other flammable vapor and liquids. 
This appliance should not be used as a drying rack for cloth-
ing, nor should Christmas stockings or decorations be hung 
in the area of it.

8.  Under no circumstances should any solid fuels (wood, coal, 

paper or cardboard etc.) be used in this appliance.

9.  The flow of combustion and ventilation air must not be ob-

structed in any way.

10. Whether the appliance is installed directly on carpeting, vinyl 

tile or any combustible material other than wood, this appli-
ance must be installed on a metal or wood panel extending 
the full width and depth of the appliance.

11. This appliance requires adequate ventilation and combus-

tion air to operate properly.

12. Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system or 
gas control that has been under water.

13. Inspect the burner before each use of the appliance. The 

burner must be replaced prior to operation if there is evi-
dence the burner is damaged. Use only burner specified by 
manufacturer.

LP-cylinder enclosures, if provided by the consumer must con-
form to the design parameters as detailed below.

Enclosures for LP-Gas Supply Systems

Enclosures for LP-gas supply cylinders shall be ventilated by 
openings at the level of the cylinder valve and at floor level. The 
effectiveness of the opening(s) for purposes of ventilation shall 
be determined with the LP-gas supply cylinder(s) in place. This 
shall be accomplished by one of the following:
a.  One side of the enclosure shall be completely open; or
b.  For an enclosure having four sides, a top and a bottom:

1.  At least two ventilation openings at cylinder valve level 

shall be provided in the side wall, equally sized, spaced at 
180 degrees (3.14rad), and unobstructed. Each opening 
shall have a total free area of not less than 1/2 square 
inch per pound (3.2 sq. cm/kg) of stored fuel capacity and 
not less than a total free area of 10 square inches (64.5 
sq. cm).

2.  Ventilation opening(s) shall be provided at floor level and 

shall have a total free area of not less than 1/2 square 
inch per pound (3.2 sq. cm/kg) of stored fuel capacity and 
not less than a total free area of 10 square inches (64.5 
sq. cm). If ventilation openings at floor level are in a side 
all, there shall be at least two openings. The bottom of 
the openings shall be at floor level and the upper edge no 
more than 5 inches (127 mm) above the floor. The open-
ings shall be equally sized, spaced at 180 degrees (3.14 
rad) and unobstructed.

3.  Every opening shall have minimum dimensions so as to 

permit the entrance of a 1/8 inch (3.2 mm) diameter rod.

Cylinder valves shall be readily accessible for hand operation. 
A door on the enclosure to gain access to the cylinder valves 
is acceptable, provided it is non-locking and can be opened 
without the use of tools.
There shall be a minimum clearance of 2 inches (51 mm) 
between the lower surface of the floor of the LP-gas supply 
cylinder enclosure and the ground.
The design of the appliance shall be such that (1) the LP-gas 
supply cylinder(s) can be connected, disconnected and the 
connections inspected and tested outside the cylinder enclo-
sure; and (2) those connections which could be disturbed when 
installing the cylinder(s) in the enclosure can be leak tested 
inside the enclosure.

Description

The ODGR Series are radiant fireplaces. Do not burn wood or 
other materials in these appliances. Each model is available 
with standing pilot for use with Natural or Propane gas units.
Report to your dealer any parts damaged in shipment.
Adequate combustion and ventilation air must be provided. The 
flow of combustion and ventilation air MUST NOT be obstruct-
ed.
Provide adequate clearances around the air opening into the 
combustion chamber; and adequate accessibility clearance for 
servicing and proper operation. NEVER obstruct the front open-
ing of the appliance.

This fireplace is not designed to be water tight. 
Therefore, when installing this unit against an exte-
rior wall, the wall must be finished before setting unit 
in place.

Содержание ODGR400

Страница 1: ...lier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instruc...

Страница 2: ...ics 11 Optional Weather Enclosures 12 Optional Stainless Steel Hood 12 Lighting Operating Instructions 13 Troubleshooting 14 Maintenance 15 Replacement Parts 16 Accessories 18 Warranty 19 Proposition 65 Warning Fuels used in gas wood burning or oil fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects and othe...

Страница 3: ...ged Use only burner specified by manufacturer LP cylinder enclosures if provided by the consumer must con form to the design parameters as detailed below Enclosures for LP Gas Supply Systems Enclosures for LP gas supply cylinders shall be ventilated by openings at the level of the cylinder valve and at floor level The effectiveness of the opening s for purposes of ventilation shall be determined w...

Страница 4: ... Access 1456M 362mm Low Voltage Wire Access Fireplace Dimensions Fig 2 ODGR500 specification and framing dimensions 36 914mm 40 1016mm 39 6 1007mm 6 1 6 m m 56O 13mm 56O 6 822mm 622mm 43 6M 1111mm 856M 210mm 56O 165mm 56O 191mm Gas Line Access Rough Opening Height 6 16mm 22 559mm 56O 572mm 559mm Recessed Nailing Flange Rough Opening Width 41 Rough Opening Depth 3 6M 95mm 1041mm 3 6 98mm 7114 ODUVS...

Страница 5: ...ide 0 0 mm Back 0 0 mm Perpendicular Sidewall 0 0 mm Top of unit to ceiling 36 914 mm Front of unit to combustibles 36 914 mm Screened Porch Installation The ODGR may be installed safely and is design certi fied by CSA to be installed in a screened porch with these guidelines Minimum porch area 96 sq feet 9 sq m Minimum celing height 92 234 cm Minimum of two 2 walls must be screened Minimum top of...

Страница 6: ... sta CFM170 DV Builder Front View O N M L K Ref Mantel Ref Mantel Leg From Leg Depth of Comb Opening F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 mm Black Surround Face CFM164 CFM170 Fig 3b Combustible mantel leg minimum installation Side of Combustion Chamber Moisture Resistance This outdoor fireplace will shed moderate amounts of ...

Страница 7: ...ove 4 500 feet 1 370 m For elevations above 4 500 feet 1 370 m instal lations must be in accordance with the current ANSI Z223 1 NFPA 54 and or local codes having jurisdiction Valve Access Valve access can be accomplished in one of two ways 1 Remove the front panel just below the front of the hearth pan This is accomplished by lifting on the panel To replace the valve access panel line up the two ...

Страница 8: ...ight side of the appliance A knockout is provided to allow for the gas pipe installation and testing of any gas con nection NOTE The gas line connection can be made with 3 8 copper tubing approved for propane or natural gas 1 2 rigid pipe or an approved flex connector then reduced to 3 8 to the appliance Because some municipalities have some additional local codes it is always best to consult your...

Страница 9: ...o gas valve Refer to Figure 11 CAUTION Do not wire millivolt remote wall switch for gas appliance to a 120v power supply For lighting instructions refer to Page 12 NOTE If glass doors are installed the unit must be operated with the doors fully open Fig 12 If the doors are not fully open the thermodisk will auto matically turn the unit off CAUTION After the unit cools the burner will automatically...

Страница 10: ...t of air will be trapped in the line When first lighting the unit with pilot light it will take a few minutes to purge the trapped air Once purg ing is complete the pilot and burner will light and operate as indicated in the instruction manual Subsequent lightings of the appliance will not require purging When lit for the first time the appliance will emit a slight odor for an hour or two This is ...

Страница 11: ... valves flame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the center of the gas control LO H I Turn counterclockwise to increase flame height Turn clockwise to lower flame height FP390 FLAME ADJUSTMENT KNOB 11 21 96 Fig 15 Flame adjustment knob for SIT820 valve Flame Characteristics It is important to periodically perform a visual check of the pilot and the burner...

Страница 12: ...ccess Cover KT458 Fig 20 Push bottom of weather enclosure into firebox Optional Stainless Steel Hood An optional stainless steel hood is available for both the ODGR400 and ODGR500 NOTE The stainless steel hood may NOT be used when the optional glass doors are installed Installation Instructions 1 Turn the unit off and allow to cool 2 Place the hood so the 2B 67 mm slot clears the sensor plate loca...

Страница 13: ...hese instructions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplie...

Страница 14: ...sk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve Turn to pilot meter should read greater than 100mV Thermodisk Pilot Lights with Piezo Ignitor YES YES YES YES Pilot Stays Lit Pilot Lights Main Burner System OK START CHECK Wall switch is not turned on Watch for grounded w...

Страница 15: ... burner gas orifice pilot burner thermopile combination millivolt gas valve Most of these components may require only an occa sional checkup and cleaning and some may require ad justment If repair is necessary it should be performed by a qualified technician In order to properly clean the burner and pilot assembly turn off the gas to the unit remove logs exposing the burner and pilot assembly Clea...

Страница 16: ... 3 Ceramic Tile single 57803 57803 4a Burner Orifice Natural Manifold Orifice 20007106 20007106 4b Burner Orifice LP Manifold Orifice 20007159 20007159 6 Side Brick Left 20002008 or 92D0004 20002021 or 92D0011 7 Back Brick 20002006 or 92D0002 20002019 or 92D0005 8 Side Brick Right 20002007 or 92D0003 20002020 or 92D0006 9 Left Hearth Brick 20007158 or 92D0008 20007241 or 92D0010 10 Right Hearth Br...

Страница 17: ... parts Parts may be ordered through your Monessen Fireplaces distributor or dealer You will need the following information when ordering re placement parts 1 The appliance model number 2 The serial number 3 A description of the part Should you need additional information beyond what your dealer can furnish contact MHSC 149 Cleveland Drive Paris KY 40361 Model and serial numbers are listed on the r...

Страница 18: ...roved component to make any modifications you may create a pos sible fire hazard and will void the MHSC warranty In addition such action may void the coverage provided by the owner s insurance Accessory Description Model Number 4 Stainless Steel For heater up to 40 000 BTU s and mantels UV36SH4 Hood 8 high by 12 wide UV42SH4 Glass Doors Designed to enhance the look of the fireplace 36GDKSSSR 42GDK...

Страница 19: ...ure dif ferentials produced by wind Broken glass components Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this fireplace to be in compliance with your local building code Building codes vary greatly throughout the country and you should determine whether your local building code contains restrictions on the use of this fireplace before you purchase it Blo...

Страница 20: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...

Отзывы: