20308636
29
AVFLST Vent Free Fireplace
MAINTENANCE AND CLEANING
PORCELAIN PANEL REMOVAL
1. Remove two (2) air deflection glass panels.
2. Remove glass media from hearth and burner area.
3. Remove two (2) screws holding top of panel in place.
See Figure 37
4. Remove single retainer clip at base of panel. See
Figure 38
5. Tilt panel out from top and remove.
6. To reinstall panel, insert at an angle with bottom
first. Tilt top in aligning holes at top and install two
retainer screws.
7. install retainer bracket at base.
4. Remove two screws holding LED control assembly
in place. See Figure 36. Turn flat and pull forward.
5. Remove the two black LED connectors.
6. From inside unit, start at one end of the strip and
begin to peel from base.
7. Repeat with second strip.
8. Peel paper from adhesive back on new LED strip
and place in track. Feed wire through hole on left
end of unit.
9. Reconnect strips to control module and replace con
-
trol module with two screws.
10. Reinstall front and rear hearth with nineteen (19)
screws.
11. Install two (2) air deflection glass panels and glass
media.
Porcelain
panel screws
Figure 37.
Porcelain Panel Screw Location
Nine Front Hearth Screws
Ten Rear Hearth Screws
Retainer clip
Figure 38.
Porcelain Panel Retainer Clip Location
Figure 39.