2.  Press the OFF/down button 

to decrease the flame height 

and  turn  off  the  fireplace. 

When the OFF/down button 

is  pressed  for  three  times, 

the flame icon changes form 

High  to  Medium,  to  Low, 

then to Off.

3.  If the OFF button is held for 

more than 3 seconds at any 

flame  height,  the  fireplace 

will  be  turned  off  and  the 

flame icon disappears.

4.  Sliding up and down on the 

arrow  buttons  can  also  turn 

on or turn off the fireplace.

5.  If the fireplace is shut off us

-

ing the above methods in 3 

and 4, all the settings will be 

remembered and will be resumed next time the fire

-

place is turned on (Memory Off).

Timer Mode

Figure 24
Press the TIMER button to en

-

ter  timer  mode.  The  fireplace 

will stay on for a period of time 

as  specified  by  the  timer  and 

then be shut off by the transmit

-

ter when the timer counts down 

to zero.
1.  When  the  TIMER  button  is 

pressed,  the  Set  Time  ap

-

pears in the frame of the but

-

ton and flashes.

2.  Use  ON/up  and  OFF/down 

to  increase  or  decrease 

the  Set  Time  in  15  min.  in

-

crements,  between  0:00  to 

6:00.  Sliding  up  and  down 

on the arrow buttons will in

-

crease or decrease the Set Time in 1 hour increments.

3.  Push the TIMER button again to confirm the Set Time, 

the transmitter sends an ON signal to turn on the fire

-

place.

4.  The flashing stops and the ON/up and OFF/down but

-

tons become flame height controller again. The flame 

height will then stay as set up by the ON/up and OFF/

down buttons.

5.  The TIMER button can be used when the transmitter 

is  in  Manual  Mode  or  in  Thermostat  Mode.  In  both 

modes,  the  fireplace  will  be  shut  down  completely 

when the timer counts down to zero.

6.  To exit Timer Mode:

a.  Push and hold the TIMER button for 3 seconds 

or

b.  Use  the  OFF/down  buttons  to  decrease  the  Set 

Time to zero

 or

c.  Slide  down  on  the  arrow  buttons  to  exit  TIMER 

mode and shut off the fireplace.

Thermostat Mode

Figure 25
Press  the  THERMO  button  to 

set  the  transmitter  in  thermo

-

stat mode. The transmitter will 

automatically  turn  on  the  fire

-

place when the room tempera

-

ture is below the set tempera

-

ture and turn off the appliance 

when  the  room  temperature 

is  above  the  set  temperature 

within one degree.
1.  When  the THERMO  button 

is pressed, the Set tempera

-

ture appears in the frame of 

the button and flashes.

2.  Use ON/up  and OFF/down  

to increase or decrease the 

Set temperature in 1 degree increments, between 45 

degrees and 90 degrees. Slide up and down on the 

arrow buttons will increase or decrease the Set Tem

-

perature in 10 degrees increments.

3.  Press  the THERMO  button  again  to  confirm  the  Set 

Temperature.  The  transmitter  will  send  out  an  On 

signal or an Off signal depending on the relationship 

between the Set temperature and the Room tempera

-

ture.

4.  The flashing stops and the ON/up  and OFF/down  but

-

tons become flame height controller again. The flame 

height will then stay as set up by the ON/up and OFF/

down buttons.

5.  To exit Thermostat Mode:

a

.  Push and hold the THERMO buttons for 3 seconds 

or

b.  Slide down on the arrow buttons to exit Thermostat 

mode and shut off the fireplace.

Smart Mode Option for Thermostat Mode

Figure 26
Press and hold the THERMO button and the ON/UP but

-

ton  at  the  same  time  for  3  seconds  to  toggle  between 

Smart Mode and the regular Thermostat Mode. The icon 

“Smart  Mode”  will  appear  under  the  Set  Temperature. 

The transmitter will automatically adjust the flame height 

according to the difference between the Set temperature 

and  the  Room  temperature.  There  is  no  manual  flame 

height adjustment.

FP2651
Manual mode

Figure 23. 

 

FP2652
Timer mode

Figure 24. 

 

FP2653
thermo mode

Figure 25. 

 

Содержание AVFLST42NTSC

Страница 1: ...ght any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supp...

Страница 2: ...ncombustible facing installation 10 Connect the gas 11 Check gas pressure 12 Gas pressures 12 ELECTRICAL INSTALLATION 13 Wiring junction box 13 FINAL INSTALLATION 15 Installation of air deflection gla...

Страница 3: ...rviced as it may not be operating properly 10 The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 l NFPA54 11 This unit complies w...

Страница 4: ...g 3 5 kPa 23 The appliance must be isolated from gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to...

Страница 5: ...FUEL MAX INPUT BTU h MIN INPUT BTU h ORIFICE SIZE AVFLST42NTSC NAT 37 000 24 500 2 20 mm AVFLST42PTSC LP 36 000 28 500 55 GAS PRESSURES NATURAL PROPANE LP Inlet Minimum 5 0 w c 11 0 w c Inlet Maximum...

Страница 6: ...nimum Rough Framing Height 32 813mm Minimum rough opening depth for 5 8 wall thickness 12 305mm Interior wall installation Exterior wall installation Minimum Rough Framing Width 44 1118mm 44 1118mm Wa...

Страница 7: ...removed from under the unit 2 Install following the instructions found in this manual 3 Field wire main power supply to junction box Refer to the Electrical Installation section page 13 Electrical co...

Страница 8: ...indow or other combustibles Refer to Clearance and Height Requirements section on Page 9 Minimum clearances to combustibles must be maintained Location must not be affected by drafts caused by kitchen...

Страница 9: ...instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fire hazard Floor Clearance The fireplace may be installed directly on a combustible floor or a...

Страница 10: ...materials which do not protrude beyond the face NONCOMBUSTIBLE FACING INSTALLATION CAUTION The noncombustible wall board supplied with this unit can be damaged if dropped or struck Handle with care 1...

Страница 11: ...T Loosen the pipe adapter on the flex tube before installing to the system piping Always use an external regulator for all propane LPG heat ers only to reduce the supply tank pressure to a maximum of...

Страница 12: ...and then place tubing to pressure gauge over test point Use test point A closest to gas inlet If the pressure is not within the range listed for your gas type turn the valve reg ulator until it is wi...

Страница 13: ...ld only be performed by a qualified licensed electrician Main power supply must be turned off before connecting to the main electrical power supply or performing service WARNING Electrical Grounding I...

Страница 14: ...lve Black Yellow Thermocouple Pilot Thermocouple Module Orange Red Plug in Connector A A C MODULE TO JUNCTION BOX IN FIREPLACE PLUG IN CONNECTOR A WHITE BLACK GREEN WHITE BLACK Opt Blower Hearth Light...

Страница 15: ...er needs to burn cleanly This may cause sooting 1 Spread fireglass evenly in one layer over the entire floor and burner It is important to not have the fireglass too thick on ported area single layer...

Страница 16: ...supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not function by hand do no...

Страница 17: ...ep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will light 6 Once pilot flame is established the main burner flame will light automatically 7 If the pil...

Страница 18: ...and pull out to remove battery door 2 Install the batteries as indicated on Command Center 3 Close battery door by snapping in place 4 When the four 4 batteries are installed the system will operate...

Страница 19: ...er is on holding the OFF button on the Command Center while turning on the master switch will activate the learn function for the transmitter 3 After the above operation two beeps will be given and th...

Страница 20: ...mmands of OFF are Memory Off the system will remember all last settings before turning off The next time the fireplace is turned on all settings will resume To reset change to the desired settings and...

Страница 21: ...tment arrows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT and AUX The adjustment arrows include ON up and OFF down Their...

Страница 22: ...tory In the event of activation or interference from other nearby transmissions change the code using the following procedures learn function must be performed af ter changing the code 1 Press the ON...

Страница 23: ...ld the TIMER button for 3 seconds or b Use the OFF down buttons to decrease the Set Time to zero or c Slide down on the arrow buttons to exit TIMER mode and shut off the fireplace Thermostat Mode Figu...

Страница 24: ...n but tons become flame height controller again 5 When the light button is flashing slide up and down on the arrow buttons will turn the light brightness to HIGH or Off directly without pressing the l...

Страница 25: ...hen the ambient temperature is less than 40 de grees Fahrenheit the LCD will display LO and NO SIGNAL will be sent to turn on the appliance All functions still remain the same for both Manual Mode and...

Страница 26: ...tteries should be changed every six 6 months Appliance does not come on The transmitter did not sync with the receiver Make sure the transmitter has synced to the receiver There will be two audible be...

Страница 27: ...d Lo and Off and cycles through the color selection Color selection options Using the color slection button you can choose from ten 10 different lighting options 1 Color fade This selection will cycle...

Страница 28: ...r intake holes Remove lint or particles with vacuum brush or pipe cleaners Failure to keep air intake holes clean will result in sooting and poor combustion Inspect and clean all burner ports Inspect...

Страница 29: ...ED control assembly in place See Figure 36 Turn flat and pull forward 5 Remove the two black LED connectors 6 From inside unit start at one end of the strip and begin to peel from base 7 Repeat with s...

Страница 30: ...patterns Sooting and improper burning will result During manufacturing fabricating and shipping various components of this appliance are treated with certain oils films or bonding agents These chemic...

Страница 31: ...with ON OFF switches off Gas odor even when control knob is in OFF position Gas leak Locate and correct all leaks Control valve defective Replace control valve Burner does not light after ODS pilot i...

Страница 32: ...onnected to the appliance Ensure that both the 3V IPI control module power supply as well as the LED power supply are securely plugged into the appliance junction box Faulty wiring Check appliance for...

Страница 33: ...heck gas supply Go through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage...

Страница 34: ...e 6 2 20303043K Medium Dark Gray Stone 7 2 20303044K Medium Tan Stone 8 2 74D0718K Small Tan Stone 9 1 78D0141K Small Dark Gray Stone 10 2 74D0717K FIREBOX ITEM DESCRIPTION QTY PART NO 1 Bulb Top Ligh...

Страница 35: ...14D0473 14D0473 5 Pilot Regulator not shown 1 14D0469 6 Control Box 1 80D0018 80D0019 7 Command Center 1 80D0005 80D0005 8 Injector 2 20305649 62D3005 9 Venturi 2 45D0600 20305775K 10 Flexhose w Shut...

Страница 36: ...time Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly dam...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...149 Cleveland Drive Paris Kentucky 40361 www monessenhearth com...

Отзывы: