background image

20308636

21

AVFLST Vent Free Fireplace

TOUCH SCREEN REMOTE CONTROL OPERATION

NOTE:

 Due to the sensitive temperature monitoring 

components in the transmitter,  it is  necessary to allow 

the transmitter to stabilize to room temperature before 

accurate room temperatures are displayed.  If the 

transmitter is activated from a severe cold condition, 

allow 15 minutes for accurate temperature readings 

to appear on the LCD display.

WARNING!!

Turn  appliance  OFF  (at  the  Master  Switch)  if  you 

are away from your house for an extended period of 

time.  Never leave anything on top of the surface of 

the transmitter.

n

  Function Areas of the LCD Display

Figure 18 shows the display of the TSFSC LCD.

Information Bar

The  information  bar  shows  the  room  temperature,  the 

“sending signal” radio icon, the low battery indication icon, 

the child-proof icon, and the flame icon. This area doesn’t 

have touch buttons.

  The room temperature will always be shown after 

power-up. It displays the room temperature from 40 

°F to 99 °F. “Lo” and “HI” will be displayed when the 

room temperature is lower than 40°F or higher than 

99°F, respectively.

  The radio icon will be shown when the transmitter is 

sending a signal.

  The low battery indication icon will be shown when 

the battery voltage is low.

  The child-proof icon will be shown when the child-

proof mode is activated.

  The flame icon indicates the current flame height – 

Off, Low, Medium and High

Touch Area

The touch area contains all touch buttons to control the 

transmitter. It consists of two categories: menus and ad

-

justment arrows. The blue LED backlight lights up for 8 

seconds when any of the touch buttons is pressed.

  The menus include TIMER, THERMO, LIGHT and 

AUX.

  The  adjustment  arrows  include  ON/up  and  OFF/

down. Their default function is to adjust the flame 

height. When a button from the menu is pressed, 

the ON/up and OFF/down buttons will temporarily 

become adjustment controls for the selected item. 

When the adjustment is done, the ON/up and OFF/

down  buttons  go  back  to  flame  height  controller 

again.

Logo Bar

The Logo Bar contains the brand logo: Signature Com

-

mand

®

 System.

n

  Initialization and Setting up

Installing Batteries:

Figure 19
The  remote  transmitter  has  two 

battery  compartments,  one  on 

each  end  of  the  transmitter.   

Al-

ways change all four (4) batter-

ies at the same time.

To install batteries,

1.  Press  down  the  battery  door 

tab and pull out to remove the 

battery door.

2.  Install the batteries as indicat

-

ed inside the battery compartments.

3.  Close the battery door by snapping in place.
4.  When  all 

four

  batteries  are  installed,  the  transmitter 

will initialize for 5 seconds and then is ready for use.

5.  The batteries should be replaced every 12 months or 

when the low battery icon indicator is displayed.

Changing Temperature Unit

When batteries are installed in the transmitter,
1.  All available icons on the LCD will be turned on then 

be cleared.

2.  The LCD will display temperature unit: °F. Use ON ∆ 

to toggle the units between °F and °C within the first 5 

seconds.

3.  The transmitter enters Manual Mode
4.  The LCD displays room temperature with the chosen 

unit.

FP2646
TSFSC display

Information

Bar

Touch 

Area

Logo 

Bar

Menus

Adjustment 

Controls

Function Areas of the LCD Display

Figure 18. 

 

FP2607
install battery

Battery 

Door 

Tabs

Figure 19. 

 

Содержание AVFLST42NTSC

Страница 1: ...ght any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supp...

Страница 2: ...ncombustible facing installation 10 Connect the gas 11 Check gas pressure 12 Gas pressures 12 ELECTRICAL INSTALLATION 13 Wiring junction box 13 FINAL INSTALLATION 15 Installation of air deflection gla...

Страница 3: ...rviced as it may not be operating properly 10 The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 l NFPA54 11 This unit complies w...

Страница 4: ...g 3 5 kPa 23 The appliance must be isolated from gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to...

Страница 5: ...FUEL MAX INPUT BTU h MIN INPUT BTU h ORIFICE SIZE AVFLST42NTSC NAT 37 000 24 500 2 20 mm AVFLST42PTSC LP 36 000 28 500 55 GAS PRESSURES NATURAL PROPANE LP Inlet Minimum 5 0 w c 11 0 w c Inlet Maximum...

Страница 6: ...nimum Rough Framing Height 32 813mm Minimum rough opening depth for 5 8 wall thickness 12 305mm Interior wall installation Exterior wall installation Minimum Rough Framing Width 44 1118mm 44 1118mm Wa...

Страница 7: ...removed from under the unit 2 Install following the instructions found in this manual 3 Field wire main power supply to junction box Refer to the Electrical Installation section page 13 Electrical co...

Страница 8: ...indow or other combustibles Refer to Clearance and Height Requirements section on Page 9 Minimum clearances to combustibles must be maintained Location must not be affected by drafts caused by kitchen...

Страница 9: ...instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fire hazard Floor Clearance The fireplace may be installed directly on a combustible floor or a...

Страница 10: ...materials which do not protrude beyond the face NONCOMBUSTIBLE FACING INSTALLATION CAUTION The noncombustible wall board supplied with this unit can be damaged if dropped or struck Handle with care 1...

Страница 11: ...T Loosen the pipe adapter on the flex tube before installing to the system piping Always use an external regulator for all propane LPG heat ers only to reduce the supply tank pressure to a maximum of...

Страница 12: ...and then place tubing to pressure gauge over test point Use test point A closest to gas inlet If the pressure is not within the range listed for your gas type turn the valve reg ulator until it is wi...

Страница 13: ...ld only be performed by a qualified licensed electrician Main power supply must be turned off before connecting to the main electrical power supply or performing service WARNING Electrical Grounding I...

Страница 14: ...lve Black Yellow Thermocouple Pilot Thermocouple Module Orange Red Plug in Connector A A C MODULE TO JUNCTION BOX IN FIREPLACE PLUG IN CONNECTOR A WHITE BLACK GREEN WHITE BLACK Opt Blower Hearth Light...

Страница 15: ...er needs to burn cleanly This may cause sooting 1 Spread fireglass evenly in one layer over the entire floor and burner It is important to not have the fireglass too thick on ported area single layer...

Страница 16: ...supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not function by hand do no...

Страница 17: ...ep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will light 6 Once pilot flame is established the main burner flame will light automatically 7 If the pil...

Страница 18: ...and pull out to remove battery door 2 Install the batteries as indicated on Command Center 3 Close battery door by snapping in place 4 When the four 4 batteries are installed the system will operate...

Страница 19: ...er is on holding the OFF button on the Command Center while turning on the master switch will activate the learn function for the transmitter 3 After the above operation two beeps will be given and th...

Страница 20: ...mmands of OFF are Memory Off the system will remember all last settings before turning off The next time the fireplace is turned on all settings will resume To reset change to the desired settings and...

Страница 21: ...tment arrows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT and AUX The adjustment arrows include ON up and OFF down Their...

Страница 22: ...tory In the event of activation or interference from other nearby transmissions change the code using the following procedures learn function must be performed af ter changing the code 1 Press the ON...

Страница 23: ...ld the TIMER button for 3 seconds or b Use the OFF down buttons to decrease the Set Time to zero or c Slide down on the arrow buttons to exit TIMER mode and shut off the fireplace Thermostat Mode Figu...

Страница 24: ...n but tons become flame height controller again 5 When the light button is flashing slide up and down on the arrow buttons will turn the light brightness to HIGH or Off directly without pressing the l...

Страница 25: ...hen the ambient temperature is less than 40 de grees Fahrenheit the LCD will display LO and NO SIGNAL will be sent to turn on the appliance All functions still remain the same for both Manual Mode and...

Страница 26: ...tteries should be changed every six 6 months Appliance does not come on The transmitter did not sync with the receiver Make sure the transmitter has synced to the receiver There will be two audible be...

Страница 27: ...d Lo and Off and cycles through the color selection Color selection options Using the color slection button you can choose from ten 10 different lighting options 1 Color fade This selection will cycle...

Страница 28: ...r intake holes Remove lint or particles with vacuum brush or pipe cleaners Failure to keep air intake holes clean will result in sooting and poor combustion Inspect and clean all burner ports Inspect...

Страница 29: ...ED control assembly in place See Figure 36 Turn flat and pull forward 5 Remove the two black LED connectors 6 From inside unit start at one end of the strip and begin to peel from base 7 Repeat with s...

Страница 30: ...patterns Sooting and improper burning will result During manufacturing fabricating and shipping various components of this appliance are treated with certain oils films or bonding agents These chemic...

Страница 31: ...with ON OFF switches off Gas odor even when control knob is in OFF position Gas leak Locate and correct all leaks Control valve defective Replace control valve Burner does not light after ODS pilot i...

Страница 32: ...onnected to the appliance Ensure that both the 3V IPI control module power supply as well as the LED power supply are securely plugged into the appliance junction box Faulty wiring Check appliance for...

Страница 33: ...heck gas supply Go through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage...

Страница 34: ...e 6 2 20303043K Medium Dark Gray Stone 7 2 20303044K Medium Tan Stone 8 2 74D0718K Small Tan Stone 9 1 78D0141K Small Dark Gray Stone 10 2 74D0717K FIREBOX ITEM DESCRIPTION QTY PART NO 1 Bulb Top Ligh...

Страница 35: ...14D0473 14D0473 5 Pilot Regulator not shown 1 14D0469 6 Control Box 1 80D0018 80D0019 7 Command Center 1 80D0005 80D0005 8 Injector 2 20305649 62D3005 9 Venturi 2 45D0600 20305775K 10 Flexhose w Shut...

Страница 36: ...time Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly dam...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...149 Cleveland Drive Paris Kentucky 40361 www monessenhearth com...

Отзывы: