26
AVFLST Vent Free Fireplace
Monessen • AVFLST42 Installation Instructions • 4118-900 Rev. B • 05/2020
IntelliFire™ Plus ODS
Power Outage
• If fireplace battery backup system IS installed at time of
power outage, fireplace operation will not be interrupted.
• If fireplace battery backup system IS NOT installed at
time of power outage, fireplace will shut off. To resume
fireplace operation, install battery backup.
NOTICE:
Battery polarity must be correct or module
damage will occur.
Manual Fireplace Shutoff
In the unlikely event that the remote wall switch malfunc-
tions and will not turn off the fireplace, call your dealer
for service assistance. In the meantime, you may choose
one of the following actions to turn off the fireplace:
CAUTION! Risk of burns!
Fireplace surfaces are hot
when operating and during cool down. Use care and wear
gloves when opening the front and accessing compo-
nents inside the fireplace.
Check remote screen for battery level indicator, replace
the batteries if low battery is indicated (See Figure 8,
page 24).
The fireplace may be manually shut down by one of the
following methods:
Turn off the control module:
• Open or remove the decorative front to access the control
module.
• Move switch to OFF (See Figure19, page 27).
Disconnect power to the control module:
• Open or remove the decorative front to access power
cord to the junction box and/or back-up batteries.
• Unplug the control module and/or remove back-up
batteries.
Shut off gas to the control:
• Open or remove the decorative front and locate the gas
shut-off valve to the left of the gas control.
• Rotate the valve 90 degrees to turn off gas supply.
Turn off power to the fireplace (if back-up batteries are
not installed):
• Unplug unit from electrical source, if you cannot unplug
then:
• Locate house circuit breaker for fireplace.
• Turn off the circuit breaker.