AVFLST Vent Free Fireplace

Monessen  •  AVFLST42 Installation Instructions  • 4118-900 Rev. B  •  05/2020

TROUBLESHOOTING

WARNING!

• 

Turn appliance OFF and allow to cool before 

servicing.

• 

Only  a  qualified  service  person  should 

service and repair the heater.

NOTE:

 All troubleshooting items are listed in order of operation.

PROBLEM

POSSIBLE CAUSE

SOLUTION

Appliance produces unwanted odors.

Appliance burning vapors from paint, hair 

spray, glues, etc.

Ventilate room. Stop using odor causing 

products while heater is running.

Gas leak.

Locate and correct all leaks.

Initial burn off.

Ventilate room and turn unit on high until 

odor is gone. Odor should be gone after 

six hours of continuous use.

Appliance shuts off during use.

Not enough fresh air is available for 

ODS/pilot to operate.

 Open window and/or door for ventilation.

Low line pressure.

Contact local gas company.

ODS/pilot is partially clogged.

Clean ODS/pilot.

Burner does not light after ODS/pilot is lit.

Burner orifice is clogged.

Burner orifice is clogged.

Burner orifice diameter is too small.

Burner orifice diameter is too small.

Inlet gas pressure is too low.

Inlet gas pressure is too low.

Burner backfires during combustion.

Manifold gas pressure is too low.

Contact local gas company.

Burner orifice is clogged.

Clean burner or replace burner orifice.

Slight smoke or odor combustion.

Burner orifice is clogged or damaged.

Clean burner or replace burner orifice.

Burner is damaged.

Replace burner.

Gas regulator defective.

Replace gas regulator.

Heater produces a whistling noise when 

burner is lit.

Air in gas line.

Operate burner until air is removed from 

line. Have gas line checked by local gas 

company.

Dirty of partially clogged burner orifices.

Clean burner or replace burner orifice.

No gas to pilot.

LP regulator shut down due to inlet 

pressure too high.

Verify LP tank regulator is installed and 

set at 11" to 13" w.c.

Replace regulator on heater.

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.  If you 

do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a prob-

lem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.  

Contact your dealer to arrange a service call by a qualified service technician.

Содержание AVFLST Series

Страница 1: ...switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your g...

Страница 2: ...cation 9 Clearances and height requirements 10 FIREPLACE INSTALLATION 12 Secure fireplace to framing 12 Finishing material 12 Noncombustible facing installation 12 Connect the gas 13 Check gas pressur...

Страница 3: ...pliance until the installation is complete This standard work checklist is to be used by the installer in conjunction with not instead of the instructions contained in this installation manual WARNING...

Страница 4: ...sh air immediately Have the heater serviced as it may not be operating properly 10 The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI...

Страница 5: ...ure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 24 Do not use this room heater if any part has been under water Immediately call a qualified servic...

Страница 6: ...RIFICE SIZE AVFLST42 CONTROLS MODEL FUEL MAX INPUT BTU h MIN INPUT BTU h ORIFICE SIZE AVFLST42NIP NAT 37 000 24 500 2 20 mm AVFLST42PIP LP 36 000 28 500 55 GAS PRESSURES NATURAL PROPANE LP Inlet Minim...

Страница 7: ...305mm Interior wall installation Exterior wall installation Minimum Rough Framing Width 44 1118mm 44 1118mm Wall cover thickness Wall cover thickness Minimum rough opening depth for 5 8 wall thicknes...

Страница 8: ...rd packing material has been removed from under the unit 2 Install following the instructions found in this manual 3 Field wire main power supply to junction box Refer to the Electrical Installation s...

Страница 9: ...wall ceiling woodwork and window or other combustibles Refer to Clearance and Height Requirements section on Page 10 Minimum clear ances to combustibles must be maintained Location must not be affecte...

Страница 10: ...ilure to follow instructions exactly can create a fire hazard Floor Clearance The fireplace may be installed directly on a combustible floor or a raised platform of an appropriate height Do not place...

Страница 11: ...installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures iden ed in the TV s technical speci ca ons Contact the...

Страница 12: ...orm constructed of combustible materials which do not protrude beyond the face NONCOMBUSTIBLEFACINGINSTALLATION CAUTION The noncombustible wall board supplied with this unit can be damaged if dropped...

Страница 13: ...vent the appliance from operating reliably Figure 10 IMPORTANT Loosen the pipe adapter on the flex tube before installing to the system piping Always use an external regulator for all propane LPG heat...

Страница 14: ...urn captured screw counterclockwise two or three turns and then place tubing to pressure gauge over test point Use test point A closest to gas inlet If the pressure is not within the range listed for...

Страница 15: ...ighten the screws 4 Make all necessary wire connections and reattach the cover plate to the outer shell WARNING Electrical connections should only be performed by a qualified licensed electrician Main...

Страница 16: ...out Refer to Figure 13 and 14 IFP ODS Wiring Diagram This appliance is equipped with an Intellifire Plus control valve which operates on a 6 volt 1 5AMP system Plug the 6 volt transformer plug into t...

Страница 17: ...LED STRIP LED STRIP TRANSFORMER CONTROL MODULE TOP BUTTON ON HI MED LO OFF BOTTOM BUTTON Color Selection RED BLUE YELLOW GREEN RED BLACK BLACK BLACK BLACK GREEN Use Y cord supplied in install bag to p...

Страница 18: ...proper amount of air the burner needs to burn cleanly This may cause sooting 1 Spread fireglass evenly in one layer over the entire floor and burner It is important to not have the fireglass too thick...

Страница 19: ...ted on the top of this label If you do not smell gas go to next step 3 To light the burner Equipped with wall switch Turn ON OFF switch to ON Equipped with remote or wall control Press ON or FLAME but...

Страница 20: ...ee Figure 18 for location Lift the barrier screen off of the appliance 2 Locate the battery tray and insert four AA cell batteries See Figure 18 Battery polarity must be correct or module damage will...

Страница 21: ...t in a separate room The remote control must be placed within 30 feet 9 14 m of the fireplace but should not be exposed to extreme heat The RC300 is approved for interior installation and should not b...

Страница 22: ...ne remote control two 6 screws two wall anchors 3 AAA batteries and one AUX300 module If batteries are properly installed the remote will turn on 1 Remove remote control components from packaging 2 Re...

Страница 23: ...nk green for 10 seconds While the LED is blinking press the POWER button on the remote control A double beep will come out of the control module to indicate that it has been programmed successfully NO...

Страница 24: ...ill not be displayed when the remote status is OFF Use the SELECT button to select the current feature Use the UP and DOWN arrows to toggle through the menu functions and value selec tions in the subm...

Страница 25: ...then press SELECT The AUX1 function can be adjusted to 4 different settings HI MED LOW and OFF Adjusting Thermostat Press the MENU button to activate the menu Using the UP and DOWN arrows highlight t...

Страница 26: ...Use care and wear gloves when opening the front and accessing compo nents inside the fireplace Check remote screen for battery level indicator replace the batteries if low battery is indicated See Fi...

Страница 27: ...as safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the RC300 remote 4 If you intend to use both an optional wired wall...

Страница 28: ...full rate after 15 minutes the flames should appear as shown in Figure 22 FLAME APPEARANCE LED CONTROL LED CONTROL Multi colored LED lights Two buttons turn LEDs On Hi Med Lo and Off and cycles throu...

Страница 29: ...w Inspect and clean burner air intake holes Remove lint or particles with vacuum brush or pipe cleaners Failure to keep air intake holes clean will result in sooting and poor combustion Inspect and cl...

Страница 30: ...base 4 Remove two screws holding LED control assembly in place See Figure 26 Turn flat and pull forward 5 Remove the two black LED connectors 6 From inside unit start at one end of the strip and begin...

Страница 31: ...certain oils films or bonding agents These chemicals are not harm ful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance possibly causing he...

Страница 32: ...small Inlet gas pressure is too low Inlet gas pressure is too low Burner backfires during combustion Manifold gas pressure is too low Contact local gas company Burner orifice is clogged Clean burner...

Страница 33: ...rify that AC power has been connected to the appliance Ensure that both the 6V IPI control module power supply as well as the LED power supply are securely plugged into the appliance junction box Faul...

Страница 34: ...voltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than 4 volts r...

Страница 35: ...se Verify connection from flame sensing rod to white sensor wire Polish flame sens ing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continu...

Страница 36: ...Bulb Socket SRV73D4521 3 Porcelain Panel Qty 2 req 20308284 4 Engine Assembly NG SRV4118 015 Propane SRV4118 016 5 Deflection Glass Qty 2 req SRV20305432 Y 6 Support Glass Painted Qty 4 req 20306020K...

Страница 37: ...454K Tube Tee to Injector 78D0090K Y Pilot Tube SRV20304115 Y Pilot Regulator NG Only SRV14D0469 Y Injector Qty 2 req NG 20305649 Propane SRV62D3005 Y 4 2 Burner Assembly NG SRV4118 013 Y Propane SRV4...

Страница 38: ...ibutor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warrant...

Страница 39: ...des 3 shipping or improper handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmenta...

Страница 40: ...Monessen a brand of Hearth Home Technologies 7571 215th Street West Lakeville MN 50044 www monessenhearth com...

Отзывы: