background image

27

AVFLST Vent Free Fireplace

Monessen  •  AVFLST42 Installation Instructions  • 4118-900 Rev. B  •  05/2020

IntelliFire™ Plus ODS

Figure 19. 

 Control Module

Control Module Operation

1.  The control module has an ON/OFF/REMOTE selector 

switch that must be set.  See Figure 19. 

  OFF Position:  Appliance will ignore all power inputs and 

will not respond to any commands from a wall switch or 

remote.  The unit should be in the OFF position during 

installation, service, battery installation, fuel conversion, 

and in the event that the control goes into LOCK-OUT 

mode as a result of an error code. 

  ON Position:  Appliance will ignite and run continuously 

in  the  HI  flame  setting,  with  no  adjustment  in  flame 

output.  This mode of operation is primarily used for 

initial installation or power outage operation with battery 

backup. 

  REMOTE Position:   Appliance will initiate commands 

from an optional wired wall switch and/or the wireless 

remote (RC300).

2.   If using a wired wall switch with the module in REMOTE 

mode, the flame output can be adjusted with the HI/LO 

selector switch on the module.  See Figure 19.  Note 

that the flame HI/LO selector switch will become inactive 

once a remote control (RC300) is programmed to the 

control module. Note that the control module will always 

ignite the fireplace on HI and remain so for the initial 10 

seconds of operation.  If the HI/LO is switched to the 

LO position, the flame output will automatically drop to 

the lowest setting after the flame has been established 

for 10 sec.  After this 10 second period, the flame can 

be adjusted from HI to LO with the switch. 

3.  The control module has safety feature that automatically 

shuts down the fireplace after 9 hours of continuous 

operation without receiving a command from the RC300 

remote.  

4.  If you intend to use both an optional wired wall switch 

and the RC300 remote control to operate your fireplace, 

the wall switch will override any commands given by 

the remote. 

5. 

Module Reset 

 

This  module  may  lock-out  under  certain  conditions.  

When  this  occurs,  the  appliance  will  not  ignite  or 

respond  to  commands.  The  module  will  go  into 

lock-out mode by emitting three audible beeps, then 

continuously displaying a RED/GREEN error code at 

its status indicator LED.

•  Check  battery  tray.    Remove  batteries  if  installed.  

Batteries should only be installed for use during power 

outages.  

•  Locate the module selector switch.  (See Figure 19).

NG/LP GAS-TYPE

SELECTOR SWITCH

SELECTOR

SWITCH

FLAME HI/LOW  

SWITCH

STATUS

 INDICATOR LED

MODULE

Detailed  Component  Operating  Instruc

-

tions— Intellifire™ Plus ODS

•  Set the module selector switch to the OFF position.
•  Wait five (5) minutes to allow possible accumulated gas 

to clear.

•  Set  the  module  selector  switch  to  ON  or  REMOTE 

position.

•  Start the appliance.

WARNING!  Risk of Explosion!  DO NOT 

press the 

module  reset  switch  more  than  one  time  within  a  five 

minute time period.  Gas could accumulate in firebox.  Call 

a qualified service technician.

Nine Hour Safety Shutdown Feature

The appliance has a safety feature that automatically 

shuts down the fireplace after nine hours of continuous 

operation without receiving a command from the wall 

switch or optional remote. 

Appliance ON/OFF

Use the IntelliFire™ Plus Remote Control to control the ON/

OFF function of the appliance.  Follow instructions included 

with the remote control.  If desired, a wall switch may be 

installed to control the ON/OFF function of the appliance.  

Содержание AVFLST Series

Страница 1: ...switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your g...

Страница 2: ...cation 9 Clearances and height requirements 10 FIREPLACE INSTALLATION 12 Secure fireplace to framing 12 Finishing material 12 Noncombustible facing installation 12 Connect the gas 13 Check gas pressur...

Страница 3: ...pliance until the installation is complete This standard work checklist is to be used by the installer in conjunction with not instead of the instructions contained in this installation manual WARNING...

Страница 4: ...sh air immediately Have the heater serviced as it may not be operating properly 10 The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI...

Страница 5: ...ure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 24 Do not use this room heater if any part has been under water Immediately call a qualified servic...

Страница 6: ...RIFICE SIZE AVFLST42 CONTROLS MODEL FUEL MAX INPUT BTU h MIN INPUT BTU h ORIFICE SIZE AVFLST42NIP NAT 37 000 24 500 2 20 mm AVFLST42PIP LP 36 000 28 500 55 GAS PRESSURES NATURAL PROPANE LP Inlet Minim...

Страница 7: ...305mm Interior wall installation Exterior wall installation Minimum Rough Framing Width 44 1118mm 44 1118mm Wall cover thickness Wall cover thickness Minimum rough opening depth for 5 8 wall thicknes...

Страница 8: ...rd packing material has been removed from under the unit 2 Install following the instructions found in this manual 3 Field wire main power supply to junction box Refer to the Electrical Installation s...

Страница 9: ...wall ceiling woodwork and window or other combustibles Refer to Clearance and Height Requirements section on Page 10 Minimum clear ances to combustibles must be maintained Location must not be affecte...

Страница 10: ...ilure to follow instructions exactly can create a fire hazard Floor Clearance The fireplace may be installed directly on a combustible floor or a raised platform of an appropriate height Do not place...

Страница 11: ...installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures iden ed in the TV s technical speci ca ons Contact the...

Страница 12: ...orm constructed of combustible materials which do not protrude beyond the face NONCOMBUSTIBLEFACINGINSTALLATION CAUTION The noncombustible wall board supplied with this unit can be damaged if dropped...

Страница 13: ...vent the appliance from operating reliably Figure 10 IMPORTANT Loosen the pipe adapter on the flex tube before installing to the system piping Always use an external regulator for all propane LPG heat...

Страница 14: ...urn captured screw counterclockwise two or three turns and then place tubing to pressure gauge over test point Use test point A closest to gas inlet If the pressure is not within the range listed for...

Страница 15: ...ighten the screws 4 Make all necessary wire connections and reattach the cover plate to the outer shell WARNING Electrical connections should only be performed by a qualified licensed electrician Main...

Страница 16: ...out Refer to Figure 13 and 14 IFP ODS Wiring Diagram This appliance is equipped with an Intellifire Plus control valve which operates on a 6 volt 1 5AMP system Plug the 6 volt transformer plug into t...

Страница 17: ...LED STRIP LED STRIP TRANSFORMER CONTROL MODULE TOP BUTTON ON HI MED LO OFF BOTTOM BUTTON Color Selection RED BLUE YELLOW GREEN RED BLACK BLACK BLACK BLACK GREEN Use Y cord supplied in install bag to p...

Страница 18: ...proper amount of air the burner needs to burn cleanly This may cause sooting 1 Spread fireglass evenly in one layer over the entire floor and burner It is important to not have the fireglass too thick...

Страница 19: ...ted on the top of this label If you do not smell gas go to next step 3 To light the burner Equipped with wall switch Turn ON OFF switch to ON Equipped with remote or wall control Press ON or FLAME but...

Страница 20: ...ee Figure 18 for location Lift the barrier screen off of the appliance 2 Locate the battery tray and insert four AA cell batteries See Figure 18 Battery polarity must be correct or module damage will...

Страница 21: ...t in a separate room The remote control must be placed within 30 feet 9 14 m of the fireplace but should not be exposed to extreme heat The RC300 is approved for interior installation and should not b...

Страница 22: ...ne remote control two 6 screws two wall anchors 3 AAA batteries and one AUX300 module If batteries are properly installed the remote will turn on 1 Remove remote control components from packaging 2 Re...

Страница 23: ...nk green for 10 seconds While the LED is blinking press the POWER button on the remote control A double beep will come out of the control module to indicate that it has been programmed successfully NO...

Страница 24: ...ill not be displayed when the remote status is OFF Use the SELECT button to select the current feature Use the UP and DOWN arrows to toggle through the menu functions and value selec tions in the subm...

Страница 25: ...then press SELECT The AUX1 function can be adjusted to 4 different settings HI MED LOW and OFF Adjusting Thermostat Press the MENU button to activate the menu Using the UP and DOWN arrows highlight t...

Страница 26: ...Use care and wear gloves when opening the front and accessing compo nents inside the fireplace Check remote screen for battery level indicator replace the batteries if low battery is indicated See Fi...

Страница 27: ...as safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the RC300 remote 4 If you intend to use both an optional wired wall...

Страница 28: ...full rate after 15 minutes the flames should appear as shown in Figure 22 FLAME APPEARANCE LED CONTROL LED CONTROL Multi colored LED lights Two buttons turn LEDs On Hi Med Lo and Off and cycles throu...

Страница 29: ...w Inspect and clean burner air intake holes Remove lint or particles with vacuum brush or pipe cleaners Failure to keep air intake holes clean will result in sooting and poor combustion Inspect and cl...

Страница 30: ...base 4 Remove two screws holding LED control assembly in place See Figure 26 Turn flat and pull forward 5 Remove the two black LED connectors 6 From inside unit start at one end of the strip and begin...

Страница 31: ...certain oils films or bonding agents These chemicals are not harm ful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance possibly causing he...

Страница 32: ...small Inlet gas pressure is too low Inlet gas pressure is too low Burner backfires during combustion Manifold gas pressure is too low Contact local gas company Burner orifice is clogged Clean burner...

Страница 33: ...rify that AC power has been connected to the appliance Ensure that both the 6V IPI control module power supply as well as the LED power supply are securely plugged into the appliance junction box Faul...

Страница 34: ...voltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than 4 volts r...

Страница 35: ...se Verify connection from flame sensing rod to white sensor wire Polish flame sens ing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continu...

Страница 36: ...Bulb Socket SRV73D4521 3 Porcelain Panel Qty 2 req 20308284 4 Engine Assembly NG SRV4118 015 Propane SRV4118 016 5 Deflection Glass Qty 2 req SRV20305432 Y 6 Support Glass Painted Qty 4 req 20306020K...

Страница 37: ...454K Tube Tee to Injector 78D0090K Y Pilot Tube SRV20304115 Y Pilot Regulator NG Only SRV14D0469 Y Injector Qty 2 req NG 20305649 Propane SRV62D3005 Y 4 2 Burner Assembly NG SRV4118 013 Y Propane SRV4...

Страница 38: ...ibutor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warrant...

Страница 39: ...des 3 shipping or improper handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmenta...

Страница 40: ...Monessen a brand of Hearth Home Technologies 7571 215th Street West Lakeville MN 50044 www monessenhearth com...

Отзывы: