28
AVFLST Vent Free Fireplace
Monessen • AVFLST42 Installation Instructions • 4118-900 Rev. B • 05/2020
Thermocouple
for LP
Thermocouple
for Natural Gas
Thermocouple
for LP
Thermocouple
for Natural Gas
FLAME APPEARANCE
Flames from the pilot, front and rear burner should be
visually checked as soon as the heater is installed.
In addition, periodically check the flames visually during
operation.
CHECK THE PILOT FLAME
The pilot flame must always be present when the
heater is in operation.
It should just touch the top of the
thermocouple tip for natural gas. Refer to
Figure 20
for
correct pilot flame.
If the pilot flame does not touch the thermocouple, then
the main burner cannot function reliably. Refer to
Figure
21
for incorrect shape of pilot flame.
CHECK THE BURNER FLAME
In normal operation, at full rate after 15 minutes, the flames
should appear as shown in Figure 22.
FLAME APPEARANCE & LED CONTROL
LED CONTROL
– Multi-colored LED lights — Two buttons turn LEDs
On (Hi/Med/Lo) and Off and cycles through the color
selection.
– Color selection options — Using the color selection
button, you can choose from ten (10) different lighting
options.
1. Color fade – This selection will cycle through the range
of colors listed below.
2. Color fade (slow) – This selection is the same as the
previous selection; only at a slower rate.
3. Pause color – This selection will allow the user to
choose a custom color through the hues of colors of
the slow fade.
• Blue
• Violet
• Red
• Yellow
• Green
• Cyan
•
White
4. Pushing the color selection button again cycles back
to the first color fade selection.
Figure 20.
Correct ODS Pilot Flame Appearance
Figure 21.
Incorrect Pilot Flame Appearance
Figure 22.
AVFLST42 Burner Flame Appearance
(Shown with fireglass only)
Figure 23.
LED Controls
ON (Hi/Med/Lo)
Off button
Color selection
button
Screws