equipment details
76
equipment details
77
Please contact Dometic Service Centres for
replacement light bulbs.
trouBLeSHootInG
Before calling the authorised Service
Department, please check whether:
1. The instructions in the section ‘Using the
refrigerator’ have been followed.
2. The refrigerator is not tilted excessively.
3. It is possible to operate the refrigerator with
an available power source
Note: The Seven Series refrigerator requires a
constant 12 volt supply for the fridge to operate
on gas. Disconnecting the leisure battery will
switch off the gas operation of the fridge.
Switching off
1. Set energy selector switch (A) to position ‘0’
(OFF). The appliance is now fully switched off.
2. Secure the door open by means of the door
stop. The door will be slightly ajar.
This is to prevent mould from forming
inside the appliance.
a
Switching off gas operation
If the refrigerator is to be taken out of service for
an extended period of time, the on-board shut-
off valve and the cylinder valve must be closed.
winter operation
1. Check that the ventilation grills and the
extractor have not been blocked by snow,
leaves or similar.
2. When the ambient temperature falls below
+8°C, the optional winter covers should
be fitted. This protects the unit from
excessively cold air.
Lower ventilation grille (L200)
upper ventilation grille with flue
vent ( L100)
3. Affix the cover and fasten it.
Tip: It is also recommended that the winter
covers should be used when the vehicle is taken
out of service for an extended period of time.
Interior light
changing the light bulbs
1. Remove cover.
2. Detach defective light bulb.
3. Fit new light bulb
4. Clip the cover back in place.
note: for 12v dc : 1 light bulb 12v, 2w
possible cause
action you can take
failure : the refrigerator does not work in gas operation mode
Gas bottle empty.
Is the supply cut-out device open?
Air in the gas pipe?
Change gas bottle.
Open the cut-out device.
Switch device off and on again 3-4 times to
remove air from the gas pipe.
failure : the refrigerator does not work on 12v
On-board fuse defective.
On-board battery discharged.
Engine not running.
Fit new fuse.
Check battery, charge it.
Start engine.
failure : the refrigerator does not work on 230v
On-board fuse defective.
No connection to supply voltage.
AES: gas operation despite connection to the
supply voltage?
Fit new fuse.
Establish power connection.
Appliance switches to gas operation due
to insufficient supply voltage (automatically
switches back to 230 V operation)
failure : the refrigerator does not cool sufficiently
Inadequate ventilation to the unit.
The thermostat setting is too low.
There is too much ice on the condenser.
Too much warm food put inside.
Appliance running for a short time.
Check that the ventilation grilles are
not covered.
Turn the thermostat to a higher setting.
Check that the refrigerator door seals
when shut.
Let food cool down first.
Wait several hours, check again.
Содержание HB095 2008
Страница 4: ......
Страница 10: ...motorhome code Code of conduct 10 The Country code 12 The Coastal code 12 ...
Страница 17: ... en route Panel van spare wheel detail 20 ...
Страница 18: ... En route 20 Panel van spare wheel detail Please refer to the Fiat handbook ...
Страница 19: ...safety security Fire 22 Carbon monoxide alarm 23 Ventilation 24 Escape paths 24 Children 24 Security 24 ...
Страница 22: ...arrival at site Positioning the motorhome 26 ...
Страница 32: ...Connecting services 42 ...
Страница 33: ...electrical systems Motorhome battery 44 LCD screen display user guide 46 Generator guidelines 51 ...
Страница 38: ...Electrical systems 52 ...
Страница 66: ...Equipment details 106 ...
Страница 71: ...Motorhome Care 114 ...
Страница 72: ...useful information Owners club aftercare 116 Useful contacts 117 Change of ownership 118 ...