5
Signal Input
+6V Out to Sensor
Common (GND)
Common (GND)
+6V Out to Sensor
Signal Input
Figure 2 Input Connector Detail (Stereo plug)
Pulse Output
from Strobe
Common (GND)
Common (GND)
Pulse Output
from Strobe
Figure 3 Output Connector Detail (Mono plug)
The input jack (
pointing into socket) enables an external signal to
trigger the strobe. Inserting a plug into the input jack will automatically
put the strobe into the external mode. The INPUT button can be used to
toggle between External Input Mode and Internal Mode. When the plug is
removed, the strobe will be put back into the Internal Mode. The polarity
of the input pulse can be set in the MENU options. In the external mode
the knob cannot be used to change the flash rate.
With no external input, the output jack (
pointing away from socket)
provides a TTL compatible pulse from the strobe’s internal oscillator.
If an external input is applied, the output pulse is in sync with the input
pulse. This output pulse may be used to trigger a second stroboscope
synchronously to illuminate larger areas. Many strobes can be “daisy
chained”. The output jack of one strobe is connected to the input jack of