background image

8

6.  Once the desired memory location is displayed, press the 

MEMORY

  button  to  store  the  current  flash  rate  in  that  location.  Press  any

  other button to cancel.

7.

 

DONE

 will be displayed.

Internal Phase Delay

Once the flash rate has been adjusted to give a stopped motion image, 

the PHASE DELAY button may be used with the knob to increase or 

decrease  the  phase  of  the  reference  mark  location.  Use  the  PHASE 

DELAY button and knob to bring a reference mark, such as a key way, 

into your line of sight.

To adjust the Phase Delay:

1.  Press the 

PHASE DELAY

 b

utton.

2. 

PHASE

 will be displayed on the bottom line and the current flash

   rate will be displayed on the top line.

3.  Turn the tuning knob to adjust the location (phase) of the reference 

 

mark.

4.  Press  the 

PHASE  DELAY

  button  again  to  turn  the  Phase  Delay 

 

mode off.

4.2  Internal Mode - TACH Frequency Generator

In the Internal Mode, the strobe can be used as a frequency generator 

(outputting  TTL  pulses)  without  having  the  strobe  flash.

 

The  pulse 

output will still occur at the flash rate; the strobe is just not flashing.

To stop flashing:

Press the 

ALT FUNCTION

 button and then the 

TACH

 button. The TACH 

icon will be displayed.

To start flashing again:

Press the 

ALT FUNCTION

 button and then the 

TACH

 button. The TACH 

icon will go away and the strobe will start flashing again.

Содержание Nova-Strobe dax

Страница 1: ...and Nova Strobe dbx Portable Deluxe Stroboscopes Instruction Manual 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarch...

Страница 2: ...void the warranty 8 There are lethal voltages present inside this product Refer to the section on Lamp Replacement before attempting to open this product 9 Do not allow cables extending from unit to...

Страница 3: ...e returnable to your distributor for recycling contact the distributor for details Monarch Instrument s Limited Warranty applies See www monarchinstrument com for details Warranty Registration and Ext...

Страница 4: ...ator 8 4 3 External Input Mode 9 4 4 Tachometer Mode External Input Required 9 4 5 Power Up Features 10 5 0 USING THE STROBOSCOPE TO MEASURE RPM 10 6 0 LAMP AND FUSE REPLACEMENT 12 6 1 Lamp Replacemen...

Страница 5: ...bottom which indicate modes flash rates etc see Figure 1 Additional information displayed include TIME Unused AUTO Unused ALT Indicates alternate function of each button lower section and knob will b...

Страница 6: ...nd RPS ALT Function Toggles Tach Mode flashing on off INPUT MEMORY Manually toggles between Internal and External Modes ALT Function Memory reads and stores 9 preset flash rates ALT FUNCTION Activates...

Страница 7: ...ate and duty cycle of operation Slower flash rates below 4 000 FPM increase the operating time Note that the strobe will not operate from the recharger supplied with the unit 2 2 Input Output Connecti...

Страница 8: ...or If an externalinputisapplied theoutputpulseisinsyncwiththeinputpulse This output pulse may be used to trigger a second stroboscope synchronously to illuminate larger areas Many strobes can be daisy...

Страница 9: ...menu items DECPT Decimal Point none 1 or 2 BLITE Backlight Yes On or No Off INPUT Positive pos or Negative neg Edge for Input Signal OUTPT Positive pos or Negative neg Edge for Output Signal 4 0 OPER...

Страница 10: ...kwise to increase the flash rate and clockwise to decrease it The knob is velocity sensitive Turn the knob slowly to have each click is equal to 0 01 FPM Turning the knob more quickly will adjust the...

Страница 11: ...kwise 2 clicks The strobe will now flash at 10 800 FPM effectively 3600 times 3 The fans blades will be all superimposed on each other One can now see if the blades are out of alignment bent etc by vi...

Страница 12: ...PHASE will be displayed on the bottom line and the current flash rate will be displayed on the top line 3 Turn the tuning knob to adjust the location phase of the reference mark 4 Press the PHASE DELA...

Страница 13: ...n an external input is supplied to the unit and the strobe is put in the Tachometer Mode the unit will read the signal from the external input sensor and display the reading on the LCD without flashin...

Страница 14: ...shaft Second the object should have some unique part on it like a bolt keyway or imperfection to use as a reference point If the object being viewed is perfectly symmetrical then the user needs to ma...

Страница 15: ...000 FPM it can be measured using the method of harmonics and multipoint calculation Start at the highest flash rate and adjust the flash rate down You will encounter multiple images so be aware of th...

Страница 16: ...USE REPLACEMENT 6 1 Lamp Replacement WARNING Beforeattemptingtoremovethelamp makesurethestroboscope is turned off and any mains cord is removed from the AC outlet Allow the lamp to cool waiting at lea...

Страница 17: ...t into place see Figure 4 Make sure the lamp is in straight and centered in the reflector hole Note Older Nova Strobes and flashtubes may have a red dot on the flashtubeandconnectortoindicatepolarity...

Страница 18: ...roboscope has a resettable fuse which will reset once conditions are normal again 7 0 BATTERY POWERED MODELS ONLY The Nova Strobe dbx is fitted with rechargeable NiMH Nickel Metal Hydride batteries Th...

Страница 19: ...BAT At this time the batteries must be recharged Remember to release the trigger switch 7 2 Charging the Batteries The unit may be recharged at any time You do not need to wait until the low battery...

Страница 20: ...sing of the battery powered strobe the user must remove the Nickel Metal Hydride batteries To do this remove the lens reflector and lamp as detailed in the Lamp Replacement section This will expose fo...

Страница 21: ...ternal Modes Flash Range and Display Same as Internal Mode external flash rates to 0 are acceptable Tachometer Mode 5 to 250 000 RPM from external trigger Accuracy 0 001 of reading or last digit Displ...

Страница 22: ...efore power down is remembered and restored on the next power up 9 user settable flash rates Flash Duration 10 25 microseconds auto adjust with flash rate Flash Tube Lamp Life 100 million flashes This...

Страница 23: ...charger 100 240 V ac 50 60 Hz Run Time 2 hours typical at 1800 FPM and over 1 hour at 6000 FPM with fully charged batteries Charge Time 4 5 hours typical with PSC 2U Weight 1 875 lbs 0 8505 kg with ba...

Страница 24: ...x Deluxe AC Stroboscope Trigger to Flash Delay 5 sec typical Light Output Average Power 15 5 W typical 4000 FPM Instantaneous per flash 230 mJoule typical to 4000 FPM Input Power AC Powered 100 V ac o...

Страница 25: ...cidental drops and infiltration of contaminants C 4027 PN 6280 034 Set of mating 1 8 3 5 mm stereo phone plugs to provide TTL signal and sensor power CA 4044 6 PN 6280 037 6 ft 1 8 m Input Output cabl...

Страница 26: ...or with 8 ft 2 5 m cable for triggering strobe ROS P 25 PN 6180 057 25 Remote Optical Sensor with 25 ft 7 6 m cable for triggering strobe IRS P PN 6180 020 Infrared Sensor with 8 ft 2 5 m cable for us...

Страница 27: ...0 046 Replacement Parts L 1903 PN 6280 030 Stroboscope replacement lamp PSC 2U PN 6280 022 Universal power supply charger 115 230 Vac with USA UK AUS Euro Adapter Plugs Internal Battery Pack PN 6280 0...

Страница 28: ...ssional s Choice Track It Data Loggers Panel Tachometers DataChart Paperless Recorders Speed Sensors Portable Tachometers Portable Strobes Frequency Converters Fixed Mounted Strobes 1071 4203 119 0622...

Отзывы: