Страница 1: ...Instruction Manual ACT 1B Series Panel Tachometers 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrument com ...

Страница 2: ...butor for details SAFEGUARDS AND PRECAUTIONS Read and follow all instructions in this manual carefully and retain this manual for future reference Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated Be sure the power supplied to this instrument matches the specification indicated on the ...

Страница 3: ...able online at www monarchinstrument com 1 0 OVERVIEW 1 2 0 INSTALLATION AND POWER 1 2 1 Installation 2 2 2 Power 2 2 3 USBProgrammingCableandSoftware 3 3 0 SENSORCONNECTIONS 3 4 0 OUTPUTOPTIONS 4 4 1 CurrentOutputOption IO 5 4 2 AnalogOutputOption AO 6 4 3 PulseRepeaterOutputOption PO 6 5 0 SPECIFICATIONS 7 6 0 OPTIONS 8 7 0 ACCESSORIES 9 APPENDIXA SerialProgrammingCommands 10 ...

Страница 4: ...sal 100 to 240 V ac 50 60Hz or optionally 12 V dc or 24 V dc isolated The ACT 1B accepts input signals from optical proximity magnetic infrared or laser sensors or direct TTL or external ac inputs The ACT 1B is suitable for panel mounting or benchtop use with convenient screw terminal connections on the rear panel of the instrument If specified at time of order placement the ACT 1B may be equipped...

Страница 5: ... connected to the terminals under the section labeled POWER on the rear panel Be sure the power supplied matches the specification indicated on the rear panel Refer to Figure 2 below If the unit is AC powered 100 240 V ac connect the live hot wire to the terminal marked L and Neutral Return wire to the terminal marked N If the unit is DC powered connect the DC supply Positive to the terminal marke...

Страница 6: ...o Figures 2 and 3 Connections and their functions are as follows VA Positive 12 V dc to provide power to optical laser infrared or amplified magnetic sensors Maximum load is 75 mA dc Optionally 5 or 24 V dc supply may be ordered PX Positive 12 V dc supply for use with two wire proximity sensors Maximum load for proper operation with two wire sensors is 25 mA SIG Positive input signal from the spee...

Страница 7: ... ordered or may be user programmed using the optional USB Programming Cable and PM Remote Software The Current or Analog Outputs are connected to the terminals in the section labeled ANALOG OUTPUT OPTION on the rear panel The actual output is marked The Pulse Output is connected to the terminals under the section labeled OUT on the rear panel CAUTION The IO or AO COM may NOT be isolated from the o...

Страница 8: ...Figure 4 below Connect the Positive side of the load to the terminal marked OUT and the other Negative side of the load to the terminal marked COM Do not use an external voltage supply Note With the internal 12 V dc compliance voltage the maximum load for the current loop is 500 ohms If the optional 24 V dc compliance option is ordered the maximum load will be 1000 ohms Figure 4 Current Output Opt...

Страница 9: ...ified at the time of purchase The output range may be programmed using the optional USB Programming Cable and PM Remote Software 4 3 Pulse Repeater Output Option PO The Pulse Repeater output provides a conditioned TTL positive going 5 V pulse out for each pulse in Connect the Positive signal wire 5 V pulse to terminal marked P and the Return to the terminal marked COM in the rear panel section lab...

Страница 10: ...ersal input for optical proximity two wire or three wire magnetic infrared or laser sensors TTL input or 2 V ac to 50 V ac peak to peak input Standard input is 1 pulse per revolution user programmable from 1 to 999 Sensor Excitation 12 V dc at 20 mA for proximity sensors 12 V dc at 75 mA for all other sensors Optional 5 or 24 V dc available Recommended Sensors Optical Monarch ROS W Proximity Monar...

Страница 11: ...mperature 32 F 122 F 0 C 50 C Humidity Maximum relative humidity 80 for temperature up to 88 F 31 C decreasing linearly to 50 relative humidity at 104 F 40 C Specifications are subject to change without notice Requires optional USB Programming Cable and PM Remote Software IO 4 to 20 mA current output AO 0 to 5 V dc analog output Note Full scale RPM must be specified for the above options when orde...

Страница 12: ...31 ROLS W Sensor Remote Optical Laser Sensor with 8 ft cable PN 6180 030 ROS W Sensor Remote Optical LED Sensor with 8 ft cable PN 6180 056 ROS P 25 Sensor Remote Optical LED Sensor with 25 ft cable must cut off plug PN 6180 057 25 ROS HT W 25 Sensor Remote Optical High Temp Sensor with 25 ft cable PN 6180 058 25 P5 11 Sensor Proximity Sensor with 10 ft cable PN 6180 013 M 190W Sensor Magnetic Sen...

Страница 13: ...on Shows Product name n Firmware revision n C2 Shows all settings D0 Sends current display value once D1 Sends display data continuously at up to display update rate D2 Stops sending data MX Sends Max reading MN Sends Min reading RE 32 Resets Max RE 64 Resets Min RE 96 Resets Max and Min CH_A TYPE Shows current type CH_A TYPE RPM Sets scale to 60 so displays in RPM CH_A TYPE FREQ Sets scale to 1 s...

Страница 14: ...Full Scale DAC1 FSCAL xxx xx Sets the Reading value that the Analog output will output Full Scale 5 V or 20 mA depends on TYPE DAC1 0SCAL Shows Analog Out Zero Scale DAC1 0SCAL xxx xx Sets the Reading value that the Analog output will output Zero Scale 0 V or 4 mA depends on TYPE default is 0 00 OUTPT Shows pulse output polarity OUTPT POS or NEG Sets pulse output polarity DISPR Shows Display Updat...

Страница 15: ...12 This page intentionally left blank ...

Страница 16: ...Instrument is committed to excellence and quality in manufacturing sales and service The Professional s Choice Track It Data Loggers Panel Tachometers DataChart Paperless Recorders Speed Sensors Portable Tachometers Portable Strobes Frequency Converters Fixed Mounted Strobes 1071 4843 114 0821 Copyright 2009 2021 Monarch Instrument All rights reserved ...