PA Mixing Amplifier  

for 5 Zones

Please read these instructions carefully prior to 
operation and keep them for later reference . All 
operating elements and connections described 
can be found on the fold-out page 3 .

Connection of the speakers (chapter 5)  

requires adequate technical knowledge in 100 V 
PA technology and is to be made by experts 
only . Operation of the amplifier is easy, even 
for adults without any expert knowledge . How-
ever, in case of any queries, please contact your 
installer or retailer .

1  Safety Notes

This unit corresponds to all relevant directives of 
the EU and is therefore marked with   .

WARNING

The unit uses dangerous mains 
voltage . Leave servicing to skilled 
personnel only and do not in-
sert anything into the air vents!

Inexpert handling may result in electric shock .
During operation, there is a hazard of con-
tact with a dangerous voltage up to 100 V at 
the speaker terminals (10, 16) . Always fold 
down the protective cover before operating 
the amplifier .
Always switch off the amplifier before making 
any connection .

• 

The unit is suitable for indoor use only . Protect 
it against dripping water and splash water, 
high air humidity and heat (admissible ambi-
ent  temperature  range:  0 – 40 °C) .

• 

Do not place any vessel filled with liquid on 
the unit, e . g . a drinking glass .

• 

Immediately disconnect the mains plug from 
the socket

1 . if the unit or the mains cable is visibly dam-

aged,

2 . if a defect might have occurred after the 

unit was dropped or suffered a similar ac-
cident,

3 . if malfunctions occur .
In any case the unit must be repaired by skilled 
personnel .

• 

Never pull the mains cable to disconnect the 
mains plug from the socket, always seize the 
plug .

• 

For cleaning only use a dry, soft cloth; never 
use water or chemicals .

• 

No guarantee claims for the unit and no liabil-
ity for any resulting personal damage or mate-
rial damage will be accepted if the unit is used 
for other purposes than originally intended, if 
it is not correctly connected or operated, if it is 
overloaded or not repaired in an expert way .

If the unit is to be put out of operation 
definitively, take it to a local recycling 
plant for a disposal which is not harm-
ful to the environment .

2  Applications

This amplifier with a 120 W RMS output volt-
age is specially designed for PA systems . Either 
use 100 V or 70 V speakers or low-resistance 
speakers (minimum impedance: 4 Ω) . With 100 V 
speakers, a wider range of applications will be 
possible . The speakers can be divided into five 
zones (fig . 4) and switched on individually or 
together using the buttons ZONES (7) .

For music reproduction, an MP3 player has 

been integrated . A USB flash drive or a USB 
hard disk with separate power supply can be 
connected to this player .
The amplifier is equipped with 6 inputs:
1 ×  microphone input MIC 1 (2) for important 

announcements taking priority over all other 
inputs, i . e . as soon as a signal is present at 
the input MIC 1, the volume of the signals 
at the other inputs will be attenuated

1 ×  line level input EM INPUT (17) for important 

announcements (e . g . from a telephone sys-
tem) taking priority over the inputs INPUT 
2 – 5 and over the MP3 player, i . e . as soon 
as a signal is present at this input, the signals 
of the inputs with lower priority and of the 
MP3 player will be faded out

2 ×  inputs INPUT 2 and INPUT 3, each input to be 

used either as a microphone input (11, 19) 
or as a line level input (20) 

 

The microphone inputs are designed as XLR 
jacks and 6 .3 mm jacks . For the XLR inputs, 
the amplification is adjustable and a 48 V 
phantom power can be activated .

2 ×   line level inputs INPUT 4 and INPUT 5 (21), 

e . g . for background music from an MP3 /  
CD player, radio or tape deck

3  Setting Up the Amplifier

The amplifier is designed for installation into 
a rack for units of a width of 482 mm (19”); 
however, it can also be used as a tabletop unit . 
In order to ensure sufficient cooling of the am-
plifier, air must always be able to flow freely 
through all air vents .

3.1  Installation into a rack

For rack installation, fasten the two mounting 
brackets with screws to the sides of the amplifier . 
For installation into a rack, the amplifier requires 
2 RS (2 rack spaces = 89 mm) . To prevent the rack 
from becoming top-heavy, insert the amplifier 
into the lower section of the rack . The front plate 
alone is not sufficient for fixing the amplifier 
safely; additionally use lateral rails or a base plate 
to secure the unit .

The hot air given off by the amplifier must 

be dissipated from the rack; otherwise, heat  
will accumulate in the rack which may not only 
damage the amplifier but also other units in 
the rack . In case of insufficient heat dissipa-
tion, install a ventilation unit into the rack (e . g . 
DPVEN-04) .

4  Operating Elements, 

Connections

4.1  Front panel

USB port of the MP3 player to connect a 
USB flash drive or a USB hard disk

Note:

 Due to the large number of storage device 

manufacturers and device drivers, it cannot be 
guaranteed that all storage media are compati-
ble with the MP3 player .

Input MIC 1 (6 .3 mm jack, unbal .) to connect 
a microphone 

 

The input MIC 1 has a priority circuit: When 
an announcement is made via this input, 
the volume of the other inputs will be auto- 
matically attenuated so that it is easier to 
understand the announcement . To adjust 
the level of volume attenuation, use the 
control MUTE LEVEL (18) .

Input level controls to mix or fade in / fade 
out the input signals

Operating elements of the MP3 player 
(

 chapter 4 .3)

Tone controls BASS and TREBLE

Control MASTER for the volume of the 
mixed signal at the line outputs and speaker 
outputs (22, 16, 10)

Buttons ZONES to switch on / off the five 
speaker groups (speaker zones) connected to 
the terminals ZONES OUTPUT (10): 
Buttons 1 – 5 for each individual zone
Button ALL for all zones

Output level indication (2 …12),
LED TEMP to indicate overheating,
LED PROT to indicate muting while switching 
on / off and to indicate a short circuit or an 
overload at the speaker outputs (10, 16)
If the LED TEMP lights up, improve the 
ventilation of the amplifier . As soon as the 
amplifier has cooled down, the LED TEMP 
will extinguish .
If the LED PROT fails to extinguish a few 
seconds after switching on or if it lights up 
during operation, switch off the amplifier 
and eliminate the overload or the short cir-
cuit at the speaker outputs (refer to chap-
ter 5) . The LED PROT will extinguish . If you 
are not able to identify the fault, consult 
skilled personnel .

POWER switch with power LED ON above

4.2  Rear panel

10 

100 V speaker terminals for five speaker 
zones; 

 

always observe chapter 5!

11 

XLR jacks (bal .) of the inputs INPUT 2 and 
INPUT 3 for microphones; as an alternative 
to the 6 .3 mm jacks (19) and the RCA jacks 
(20)

12 

Buttons PHANTOM POWER to activate the 
48 V phantom power for the XLR jacks (11)

Caution!

 When the phantom power has 

been activated, do not connect any micro-
phone with unbalanced output to the cor-
responding XLR jack (11); the microphone 
may be damaged .

13 

Controls GAIN to adjust the amplification 
(microphone sensitivity) for the XLR micro-
phone inputs (11)

14 

 Mains jack for connection to a socket 
(230 V / 50 Hz) via the mains cable provided

Содержание PA-312DMP

Страница 1: ...ALISTS BEDIENUNGSANLEITUNG INSTRUCTION MANUAL MODE D EMPLOI ISTRUZIONI PER L USO GEBRUIKSAANWIJZING MANUAL DE INSTRUCCIONES INSTRUKCJA OBS UGI SIKKERHEDSOPLYSNINGER S KERHETSF RESKRIFTER TURVALLISUUDE...

Страница 2: ...Page 8 Italiano Pagina 10 Nederlands Pagina 12 Espa ol P gina 14 Polski Strona 16 Dansk Sida 18 Svenska Sidan 18 Suomi Sivulta 19 ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FO...

Страница 3: ...PUT 5 FUSE 230 V 50 Hz 0 30 dB 1 14 15 16 17 18 19 20 21 22 2 3 10 11 12 13 4 5 6 7 8 9 COM COM COM 4 16 70V 100V OUTPUT COM COM COM 4 16 70V 100V OUTPUT COM COM COM 4 16 70V 100V OUTPUT COM COM COM 4...

Страница 4: ...g nge sind als XLR und 6 3 mm Klinkenbuchsen vorhanden wobei f r die XLR Eing nge die Verst rkung ein stellbar und eine 48 V Phantomspeisung zuschaltbar ist 2 Line Pegel Eing nge INPUT 4 und INPUT 5 2...

Страница 5: ...75V 600 Eing nge Empfindlichkeit Impedanz Anschluss MIC 1 5mV 600 6 3 mm Klinke asym INPUT 2 INPUT 3 MIC 5mV 600 ber XLR sym oder 2 5mV 2k ber 6 3 mm Klinke asym LINE 750mV 10k Cinch INPUT 4 INPUT 5 3...

Страница 6: ...3mm jacks For the XLR inputs the amplification is adjustable and a 48V phantom power can be activated 2 line level inputs INPUT 4 and INPUT 5 21 e g for background music from an MP3 CD player radio o...

Страница 7: ...E 750mV 10k RCA INPUT 4 INPUT 5 350mV 10k RCA EM INPUT 775mV 10k screw terminals unbal Phantom power for MIC 2 MIC 3 XLR 48V to be activated Frequency range 50 16000Hz Tone controls BASS 10dB 100Hz TR...

Страница 8: ...s 2 entr es INPUT 2 et INPUT 3 utilisables res pectivement comme entr e micro 11 19 ou comme entr e niveau ligne 20 Les entr es micro sont disponibles en prises XLR et jack 6 35 femelles Pour les ent...

Страница 9: ...Sorties Haut parleurs 4 16 70 100V LINE 0 775V 600 Entr es Sensibilit Imp dance branchement MIC 1 5mV 600 jack 6 35 asym INPUT 2 INPUT 3 MIC 5mV 600 par XLR sym ou 2 5mV 2k par jack 6 35 asym LINE 750...

Страница 10: ...come prese XLR e come prese jack 6 3mm per gli ingressi XLR l amplificazione pu essere regolata e si pu attivare un alimentazione phantom di 48V 2 ingressi con livello Line INPUT 4 e INPUT 5 21 p es p...

Страница 11: ...tatto MIC 1 5mV 600 jack 6 3mm sbil INPUT 2 INPUT 3 MIC 5mV 600 con XLR bil oppure 2 5mV 2k con jack 6 3mm sbil LINE 750mV 10k RCA INPUT 4 INPUT 5 350mV 10k RCA EM INPUT 775mV 10k contatti a vite sbil...

Страница 12: ...s XLR en 6 3mm jacks beschikbaar voor de XLR ingangen kunt u de versterking instellen en een fantoomvoeding van 48V inschakelen 2 lijnniveau ingangen INPUT 4 en INPUT 5 21 b v voor achtergrondmuziek v...

Страница 13: ...3 MIC 5mV 600 via XLR gebalanceerd of 2 5mV 2k via 6 3mm jack ongebalanceerd LINE 750mV 10k Cinch INPUT 4 INPUT 5 350mV 10k Cinch EM INPUT 775mV 10k schroefaansluitingen ongebalanceerd Fantoomspannin...

Страница 14: ...uede utilizar como entrada de micr fono 11 19 o como entrada de nivel de l nea 20 Las entradas de micr fono est n disponibles como tomas XLR y jack 6 3 mm Para las en tradas XLR se puede ajustar la am...

Страница 15: ...ncia conexi n MIC 1 5mV 600 jack 6 3mm asim INPUT 2 INPUT 3 MIC 5mV 600 mediante XLR sim o 2 5mV 2k mediante jack 6 3mm asim LINE 750mV 10k RCA INPUT 4 INPUT 5 350mV 10k RCA EM INPUT 775mV 10k termina...

Страница 16: ...wej cie powoduje wyciszenie pozosta ych sygna w 2 wej ciaINPUT2orazINPUT3 wykorzystywane jako mikrofonowe 11 19 lub liniowe 20 Wej cia mikrofonowe zrealizowane s na gniazdach XLR oraz 6 3mm Gniazda X...

Страница 17: ...nale rubowe niesym Zasilanie phantom dla MIC 2 MIC 3 XLR 48V w czane Pasmo przenoszenia 50 16000Hz Regulatory barwy BASS 10dB 100Hz TREBLE 10dB 10kHz Stosunek S N MIC 66dB LINE 80dB Zasilanie 230V 50H...

Страница 18: ...in struktionsmanual f r eftertryckas i n gon form eller p n got s tt anv ndas i kommersiellt syfte L s nedenst ende sikkerhedsoplysninger op m rksomt igennem f r ibrugtagning af enhe den Bortset fra s...

Страница 19: ...laitetta jos 1 virtajohdossa on havaittava vaurio 2 putoaminen tai muu vastaava vahinko on saattanut aiheuttaa vaurion 3 laitteessa esiintyy toimintah iri it Kaikissa n iss tapauksissa laite tulee to...

Страница 20: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1614 99 02 02 2019...

Отзывы: