![Monacor PA-1500D Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/monacor/pa-1500d/pa-1500d_instruction-manual_1824716007.webp)
7
English
Italiano
Italiano Pagina
Español
Español Página
Nederlands
Nederlands Pagina
Polski
Polski Strona
CONTACT
MAX 1A
0dBu (0.775 V)
30
kΩ BAL
OFF: FAULT
ON: NORMAL
MAX 0.1A
GND
OUT PRI
CTL
24V
PA-6FD
G
0
10
0
10
0dBu (0.775 V)
30
kΩ BAL
G
PA-6FD
FAULT DETECTION MODULE
GND
200
Hz
SLEEP
CO
M
20
CO
M
100
V
BALANCED
OUTPUTS
24
V
/35.5
A
FUSE
FUSE RATING
500
WRMS
FU
SE
40
1 2 3
ON
230 V~/50 Hz
PA-1500D
MONO CLASS D PA MIXING
AMPLIFIER
MONACOR INTERNATIONAL • ZUM FALSCH 36 • 28307 BREMEN • GERMANY
230 V~ / 50 Hz / 1015 VA
T6.3AL
24V /35.5 A
LEVEL
LEVEL
FD/PRIORITY
CONTROL
PRIORITY
INPUT
PRI
RELAY
PGM
INPUT
POWER
REMOTE
T40AL
PA-1500D
OCP RESET
FAULT
PROTECT
CLIP
SIGNAL
ON
STAND BY
PRIORITY
SLEEP
POWER
4
5
6
7
8
9
10
11
13 14 15 16
18
2
19
3
1
12
17
English
English Page
PA Power Amplifier
These instructions are intended for installers
with specific knowledge in sound reproduc-
tion using 100 V technology . Please read the
instructions carefully prior to installation and
keep them for later reference .
1 Applications
The amplifier PA-1500D with a rated output
power of 500 W is specially designed for
applications in PA systems . It is equipped with
a line level input for background music and
standard announcements . A second line level
input is provided for emergency announce-
ments or other important announcements .
A separate switch or an external relay can be
used for switching over to the second input .
2 Overview
Note:
To make handling easier, all green terminal
strips can be disconnected from their plug-in con-
nections .
1
LED indicators
FAULT
will light up to indicate a fault in the
amplifier
PROTECT
will light up to indicate overheating or
a fault in the amplifier
CLIP
will light up to indicate overload
[turn back the volume control LEVEL (12)
or (17)]
SIGNAL
will light up when a specific signal level
is reached
ON
power LED
STAND BY
will light up when the amplifier is
connected to the 230 V mains and is
switched off with the power switch (3)
PRIORITY
will light up when the connection
PRI CTL (16) is used to switch over
the amplifier to the input PRIORITY
INPUT (18)
SLEEP
will light up when there is no input
signal and the amplifier is in the sleep
mode to save power
2
Reset button (recessed) for the protective
circuit
3
POWER switch
4
Ground connection
5
Mains jack for connection to a mains
socket (230 V/ 50 Hz) via the mains cable
provided
6
Support for the mains fuse;
always replace a blown fuse by one of
the same type
7
Connection POWER REMOTE for an ex-
ternal switch used for remote-controlled
activation/deactivation
Note:
When using the remote control feature,
make sure that the amplifier has not been
switched on with the POWER switch (3) .
8
Connection 24 V
⎓
for a 24 V emergency
power supply unit
9
Fuse for the 24 V power supply;
always replace a blown fuse by one of
the same type
10
Speaker terminals
BALANCED
OUTPUTS
11
Connection for the internal relay: The
relay will respond when the connection
PRI CTL (16) is used to switch the amplifier
to the input PRIORITY INPUT (18) .
12
Volume control LEVEL for the input PGM
INPUT (13)
13
Balanced line level input PGM INPUT
for standard announcements and back-
ground music
14
DIP switches
No. 1
to activate / deactivate the automatic
sleep mode to save power (chapter 6,
step 6)
No. 2
to activate / deactivate the 200 Hz
high-pass filter (for attenuating the low
frequencies in order to improve speech
intelligibility)
No. 3
for module PA-6FD (accessory,
chapter 4)
lower position ON: without PA-6FD
upper position: with PA-6FD
15
LED indicator: will light up to indicate cor-
rect operation of the amplifier
16
Connection
+24V / GND
for the 24 V aux-
iliary voltage, current rating: 0 .1 A
Connection
PRI CTL / GND
for a prior-
ity switch: When the switch is closed,
the amplifier will switch from the input
PGM INPUT (13) to the input PRIORITY
INPUT (18)
17
Volume control LEVEL for the input PRI-
ORITY INPUT (18)
18
Balanced line level input PRIORITY INPUT
for important announcements – also see
items 16 and 17
19
Cover plate; will be removed when the
fault detection module PA-6FD is installed
3 Safety Notes
This unit corresponds to all relevant directives
of the EU and is therefore marked with .
WARNING
The unit uses dangerous
mains voltage . Leave servicing
to skilled personnel only and
never insert anything into the
air vents: Risk of electric shock!
During operation, there is a hazard of con-
tact with a dangerous voltage of up to 100 V
at the speaker terminals
BALANCED
OUTPUTS
(10) . Always
switch off the amplifier before making or
changing any connections .
•
The unit is suitable for indoor use only . Pro-
tect it against dripping water, splash water
and high air humidity . The admissible ambi-
ent temperature range is 0 – 40 °C .
•
Do not place any vessel filled with liquid on
the unit, e . g . a drinking glass .
•
The heat produced inside the unit must be
dissipated by air circulation . Never cover
the air vents of the housing .
•
Immediately disconnect the mains plug
from the socket
1 . if the unit or the mains cable is visibly
damaged,
2 . if a defect might have occurred after the
unit was dropped or suffered a similar
accident,
3 . if malfunctions occur .
In any case, the unit must be repaired by
skilled personnel .
•
Never pull the mains cable to disconnect
the mains plug from the socket, always
seize the plug .
•
For cleaning only use a dry, soft cloth; never
use water or chemicals .
•
No guarantee claims for the unit and no
liability for any resulting personal damage
or material damage will be accepted if the
unit is used for other purposes than orig-
inally intended, if it is not correctly con-
nected or operated, or if it is not repaired
in an expert way .
If the unit is to be put out of oper-
ation definitively, take it to a local
recycling plant for a disposal which
is not harmful to the environment .