Installation of the heating cable
• Set the cable near the connection box and regularly lace the heating wire respecting the distance between the
sections; 76 mm (3”) minimum;
• Do not bend the cable at 90° when setting it in the strapping hooks; leave a 25 mm (1“) radius. This radius
comes naturally; the cable must not be forced to have a tight bend;
• A tag is located at 50% of the cable length. During installation of the product, verify the cable half tag to
compare with your cable layout planification. Adjust pattern with the result to cover the surface. If the cable is
too long, use the buffer zone to spend the remaining cable. Never shorten the heating cable. The heating cable
must not be shortened, neither cut;
• Always start the cable at least 76 mm (3”) from the walls;
• It is important not to subject the heating cable to any mechanical strain
(stretching, bending radius under 25 mm [1”], scoring).
• Avoid walking on the cables.
N
ev
er
cut
the heating c
ab
le
N
ev
er
s
ta
pl
e
th
e h
eating cable to
th
e s
ub
flo
or
N
ev
er
s
ta
pl
e t
he
floor
sensor t
o th
e s
ub
flo
or
D
o
no
t l
ay
he
avy items on t
he
ca
ble
2) Second insulation and resistance test.
After the installation of the heating cable, measure the cable’s
electrical and insulation resistance and record the readings on line
2) After cable installation.
IMPORTANT!
Figure 8