Figure 2-1
PRESS
PRESS QUICK
CHANGE
MOUNTING PLATE
SHUT HEIGHT
GAUGE
Read the following instructions before attempting to operate the applicators.
2.1 Shut Height
The Molex FineAdjust Applicators are designed to operate in crimp
presses with standard shut height of 135.80mm (5.346").
Installation in crimp presses with other than standard shut heights
can cause severe tool breakage. It is recommended that before
installation, a check of the shut height be performed. The correct
shut height is required to prevent the punches from hitting the anvils
and the cut-off tooling from bottoming out on the base plate. It also
allows the movement of applicators from press to similar press
without adjusting the applicator or press shut height.
The shut height of the press can be checked with a shut height
gauge, which is calibrated under load to achieve the
135.80mm
(5.346") measurement. It is recommended that the shut height be
checked monthly. A shut height gauge is available from most press
manufacturers.
Measuring Press Shut Height
1.
Always disconnect the power supply from the press. Remove the machine guards if necessary.
2.
Remove the applicator from the press. See “Applicator Installation and Removal” (below) for additional information. Make
sure that the bottom of the press ram and quick change mounting plate are free from foreign material.
3.
Place the shut height gauge into the press on the press quick change mounting plate. See Figure 2-1.
4.
Manually cycle the press to the down stroke position. (Follow press manufacturer’s instructions on manually cycling the
press.)
5.
Read the shut height measurement from the front of the gauge. Follow gauge manufacturers’ instruction, usually the gauge
reads “0” when set correctly.
6.
If adjustments are necessary, refer to the press manufacturer for adjustment of the press shut height.
7.
Repeat the above steps until the correct shut height is obtained.
8.
Shut height gauges must be calibrated on a regular basis.
2.2 Set-Up
IMPORTANT
Power must be shut off and electrical cord disconnected. Manual press cycling is an
absolutely required procedure
for safety and preventing equipment damage. Always cycle by hand when trouble shooting or changing adjustments,
tooling, applicator, or accessories.
The principal mechanical parts of the FineAdjust are illustrated in Section 4.1 Assembly Drawings.
Applicator Installation and Removal
1
All presses must be equipped with a common universal type quick-change mounting plate and adapter on the press.
Contact the press manufacturer for specific information.
2
Always turn off and disconnect the power supply to the press. Remove the press guards.
3
Clean the quick change mounting plate of scrap or chips that may interfere with the FineAdjust applicator installation.
4
For the TM-2000 and TM-3000 Presses follow the procedure below:
a.
Using a 4mm hex wrench, turn the M5 SHCS clockwise until the locking clamp is fully opened.
b.
Visually align the applicator base plate slots with the location clamps on the press quick-change mounting plate.