TM-3000 and TM-4000 Universal Press
Doc. No: TM-638017299
Release Date: 06-06-05
UNCONTROLLED COPY
Page 7 of 36
Revision: F
Revision Date: 11-27-18
Transport/Storage Environment Requirements
Temperature:
-20°C to 60°C (-4°F to 140°F); 70°C (158°F) allowed for less than 24 hours
Humidity:
Less than 90% relative humidity, non-condensing
Atmospheric Pressure:
86-106KPa (12.5-15.4 psi)
The TM-3000 and TM-40000 press systems require only electrical power, however these press systems include an air valve
for air feed applicators where air is required (Mylar Tape Applicators for example).
Pneumatic Requirements (Air Feed Applicators Only)
5 bar (72 psi) minimum, 10 bar (145 psi) maximum
1.7 m³/h (1 SCFM) minimum flow
Included:
¼” NPT inlet with push-in fitting for ¼” OD tube.
Production Rate
TM-3000: 2,400 terminations per hour maximum, depending on operator skill, terminal and wire length.
TM-4000 press has a slightly slower cycle rate due to gear reduction to meet force capability.
Processing Capability
TM-3000 press output = 4,000 lbs. (18kN).
Copper conductors up to 10 AWG (5.0mm²) in stranded wire.
TM-4000 Press output = 7,000 lbs. (31kN).
Copper conductors up to 4 AWG (21.0mm²) in stranded wire, insulated or un-insulated connector products.
Copper conductors up to 2 AWG (34.0mm²) in stranded wire, un-insulated connector products only.
Sound Level
Operator will be exposed to less than 70 dBA.
1.4
Delivery Check
After removing the packaging band, lift off the top and sides of the box. The following items are included in this package:
Quantity
Press Assembly
1
63801-7290 Reel Support Assembly
1
63801-7264 Hand Cycle Wrench
1
63801-7271 Foot Pedal
1
TM-638007299 Operation Manual
1
Carton Contents
Quantity
69018-6237 Power Cord 110V with 110V NEMA 5-15P plug
(for 63801-7200)
1
(for 200-240VAC presses)
62500-1774 Power Cord with 220V NEMA 6-15P plug
1
Power Cord with CEE-V7 Euro plug
1
Power Cord with BS 1363 plug
1