TM-3000 and TM-4000 Universal Press
Doc. No: TM-638017299
Release Date: 06-06-05
UNCONTROLLED COPY
Page 17 of 36
Revision: F
Revision Date: 11-27-18
QUICK
CHANGE
PLATE
LOCATOR
CLAMPS
LOCKING
CLAMP
USE 4mm
HEX WRENCH
ENGAGE
PRESS YOKE
BASE
PLATE
LUG BOLT
PRESS
YOKE
RAM
SPACER
Figure 3-1
3.1
Applicator
Installation
Always
turn off and disconnect the power supply to the press. Turn off the “POWER” switch located on the control
panel.
Note:
Once the press guard is open, the guard sensor will disconnect power to the motor.
Steps
1.
Swing the press guard open.
2.
Verify that the applicator is correctly tooled for the
terminal being used. (Refer to specification sheets
supplied with the applicator).
3.
Clean the press quick change mounting plate of
scrap or chips that may interfere with the applicator
installation. Use a soft brush, not compressed air.
4.
Using a 4mm hex wrench, turn the M5 socket head
screw clockwise until the locking clamp is fully
opened.
5.
Slide the applicator lug bolt in the press yoke. See
Figure 3-1.
6.
Pull down on the applicator base plate slots with the
locator clamps on the press quick change plate.
7.
To lock applicator, turn M5 socket head screw
counterclockwise until tight.
8.
Confirm that the applicator is secured properly.
9.
Remove the ram spacer prior to hand cycling the
press.
Note:
A ram spacer should be used when storing or transporting your applicator. Remove ram spacer proir to hand cycling
the press and replace it before removing the applicator from the press to avoid potenial damage to the tooling.
3.2
Air Feed Applicator Installation
Always
turn off and disconnect the power supply to the press. Turn off the “POWER” switch located on the control
panel.
Note:
Once the press guard is open, the guard sensor will disconnect power to the motor.
Warning:
When using air feed applicators, always use the slide valve to shut off and vent air pressure before
servicing. The guard interlock switch
DOES NOT
remove air pressure. If an air feed is jammed and air pressure is
not removed before servicing, the feed could move unexpectedly and cause injury.
Steps
1.
Open the press guard door.
2.
Verify that the applicator is correctly tooled for the terminal being used. (Refer to specification sheets supplied with the
applicator).
3.
Clean the press quick change mounting plate of scrap or chips that may interfere with the applicator installation. Use a
soft brush, not compressed air.
4.
Using a 4mm hex wrench, turn the M5 socket head screw clockwise until the locking clamp is fully opened.
5.
Slide the applicator lug bolt in the press yoke. See Figure 3-1.
6.
Pull down on the the applicator base plate slots with the locator clamps on the press quick change mounting plate.
7.
To lock the applicator, turn the M5 socket head screw counterclockwise until tight.