General Description
1.1
Description
The 63801-7200/63801-7300 TM-3000 Universal Press and the 63801-7600 TM-4000 Universal Press are economical,
electrically-operated, single-cycle and split cycle direct drive presses. They are designed to provide an effective method of
applying a wide range of side-feed and rear-feed terminals to a pre-stripped discrete wire or cable. Both the TM-3000 and the
TM-4000 are suited to mid-volume semi-automatic operations.
Production flexibility is obtained using interchangeable FineAdjust, Mini-Mac or FA2 applicators and most industry-standard
applicators.
These presses will complete one crimping cycle with each actuation of the foot pedal (two foot pedal actuations for split cycle).
Safe operation is provided by a sensor that prevents press operation if the safety guard is opened or removed.
These presses also have a secondary sensor in the back of the motor (where the hand cycle wrench is used) to prevent the
press from operating if the hand cycle wrench is accidently left in the motor.
1.2
Features
Utilizes FineAdjust, Mini-Mac and FA2 applicators (side and rear feed), and most industry-standard applicators
Press is calibrated to 135.80mm (5.346”) industry shut height
Ideal for mid-volume, semi-automatic applications
Guarding for operator safety, including sensors for guard closed and the hand cycle wrench removed
Resettable counter for accurate batch counting
1.3
Technical Specifications
Dimensions with reel mounted
Height
1,210mm (47.60“)
Width
648mm (25.50“)
Depth
559mm (22.00“)
Unpacked weight
113.4kg (250 lb)
Shipping weight
140.61kg (310 lb)
Press Stroke
TM-3000
30mm (1.125”)
TM-4000
30mm (1.125”)
Power Requirements
Voltage:
63801-7200 TM-3000 – 100-120VAC 50-60 Hz, 4A, single phase, grounded supply
Voltage:
63801-7300 TM-3000 – 200-240VAC 50-60 Hz, 2A, single phase, grounded supply
Voltage:
63801-7600 TM-4000 – 200-240VAC 50-60 Hz, 2A, single phase, grounded supply
Note:
If 200-240VAC power is not available, then 100-120VAC power may be used with Molex step-up transformer 62500-
2992.
Operating Environment Requirements
Temperature:
-10°C to 40°C (14°F to 104°F)
Humidity:
Less than 90% relative humidity, non-condensing/non-freezing
Atmospheric Pressure:
86-106KPa (12.5-15.4 psi)
Altitude:
1,000m (3,280 ft.) maximum