Installation Preparation

1. Carefully remove the ESK from the packaging.
2. Remove the protective covering of the convector trough.
3. Under  the  protection  cover  (marked  with  a  point)  you  will  find  the  
  required accessories for connection.
4. The  final  removal  of  the  trough  cover  should  only  be  made  after  
  construction is complete.

Installation

Height Adjustment  

There are 4 types of Adjustment Blocks for adjusting the height and level-
ling the convector unit:

6 Adjustment Blocks are included with delivery of each ESK: 3 sets of  
Outer Adjustment Blocks.

A

Free/Full load Capacity

Interior adjustment blocks for ESK on the fan side are only available with 
a distance of 500 mm.

The following applies for free/complete step-on ability in case of exterior 
adjustment blocks without support:

• capacity up to 130 kg/m if distance between support max 500 mm
• capacity up to 180 kg/m if distance between support max 400 mm

kg

 

130

A = 500 mm

kg

 

180

A = 400 mm

Top view

  •

  

Outer Adjustment Blocks 

    with Feet JBA 8.80 

  •

 

 Inner Adjustment Blocks

    with Feet JBI 8.80

  •

  

Outer Adjustment Blocks 

   

with Anchors JBA 8.80

   •  Inner Adjustment Blocks
    with Anchors JBI 8.80

The number of included Adjustment Blocks (JB) is only enough for level-
ling purposes! To handle a full load, i.e. for traverse, the ESK must be fur-
ther supported by either a pressure (and heat) resistant insulation or an 
increased number of Adjustment Blocks (see free / full load capacities)!

Содержание ESK 180-110

Страница 1: ...e 4 Product Description 4 Areas of Application 4 Dimensions 5 Technical Data 5 Identification Label 5 Preconditions 6 Expert Knowledge 6 Site of Installation 6 Installation Situation 6 Operating Mode 7 Convection Principle 7 Installation 8 Installation Preparation 8 Height Adjustment 8 Free Full load Capacity 8 Installation Preparation 9 Protection Cover 9 System Extensions 10 Electrical Connectio...

Страница 2: ...Produktübersicht 2 Lieferumfang 2 Standardkomponenten 2 Optionale Komponenten 2 Geräteübersicht 4 Produktinformationen 5 Bestimmungsgemäße Verwendung 5 Produktbeschreibung 5 Einsatzbereiche 5 Abmessungen 6 Technische Daten 6 Typenschild 6 Konformitätszeichen 6 Voraussetzungen 7 Fachkenntnisse 7 Montageort 7 Funktionsweise 8 Konvektionsprinzip 8 Montage 9 Montagevorbereitung 9 Höhenjustierung 9 Fre...

Страница 3: ...oduct Overview Overview Temperature switch and safety fuse Heat exchanger Height Adjustment Blocks Endplate Control box ELS 1000 System trough Air channeling bar System bulkhead Electrical heating rod 1 2 3 4 5 6 7 8 9 4 1 2 3 5 6 7 8 2 9 ...

Страница 4: ...t be performed as fixed connection Height adaptation is possible by means of adjustment blocks The convector is covered with a covering grille which can be removed by hand the designer roll grille The desi gner roll grille is fixed with roll grille protectors Product Description The Electric System Convector ESK is used when the architectural situation requires an economical and comfortable room h...

Страница 5: ... switch Integrated into heat exchanger for protection against defective thermostats or accidental covering of unit Fuse up to 3 x 6 3 AT circuit protection in connection boxes depending on variant Protection class I Protection type IP 20 CE rating EN 60335 Convector length see identification label Electric plug terminal for max cable width 2 5 mm Window view right left on request Once the fuse is ...

Страница 6: ...rately Expert Knowledge Preconditions Installation Situation 3 Connection line 2 Border acoustic insulation 1 Continuously elastic border strips Screed and flooring particularly hardwood flooring can compress the trough of the under floor convector due to the thermal proper ties We recommend the planning and use of proper insulation duri ng the installation phase The electrical connection is norma...

Страница 7: ...7 ENG 8 D24 53 031 12 ESK 180 110 1 cooled air cold air gradient 2 warmed air for cold air barrier and room heating Convection Principle Natural Convection Heating 1 2 ...

Страница 8: ...for ESK on the fan side are only available with a distance of 500 mm The following applies for free complete step on ability in case of exterior adjustment blocks without support capacity up to 130 kg m if distance between support max 500 mm capacity up to 180 kg m if distance between support max 400 mm kg 130 A 500 mm kg 180 A 400 mm Top view Outer Adjustment Blocks with Feet JBA 8 80 Inner Adjus...

Страница 9: ...paration To prevent the movement or warping of the ESK during the use of wet or hot screed we recommend that the unit be anchored in at least 4 points to the unfinished floor with Adjustment Blocks Protection Cover Remove the protective cover permanently only after finishing the installati on of the system convector and after finishing all building work By this you avoid contamination and damage t...

Страница 10: ...e delivered ready to plug in they are also installed with system connectors Installation Electrical Connection Note for electrical connection there are 3 heating element types 220 W 500 mm length 470 W 1000 mm length 570 W 1250 mm length All ESK are equipped with the ELS 1000 for the electrical connection Through this controller the resistance and control current are in relation to the connection ...

Страница 11: ...ection and circuit diagrams are given without electrical protection devices measures Installation Optional controller for temperature setback without an Alpha Thermostat Control Circuit Plan AR 2010 K2 S AR 2010 S2 S AR 2010 C2 S DS 1000 AS 1000 ...

Страница 12: ...1000 Detailed Connection Plan Connecting box 1 ELS 1000 HP 1 HP 2 HP 3 ELS 1000 Heating cartridge HP 2 Heating cartridge HP 3 Heating cartridge HP 1 Thermostatic switch 2 Thermostatic switch 3 Thermostatic switch 1 Connecting box 1 PE 6 3 AT 6 3 AT PE L N N N L L PE 1 3 5 2 4 6 N L PE L L N N ...

Страница 13: ...s without Alpha Thermostat Control e g DS 1000 Alpha Thermostat 230 V AC with Mounting Base AS 1000 A further wiring of the mains line via the connection terminals of the circuit boards is inadmissible We therefore recommend cor responding terminals to be provided by the customer L L N N L L N N L L N N N L PE Through connection 1 3 5 2 4 6 ...

Страница 14: ... rod connectors gummed step on acoustic insulation and its exterior fixing lugs are located below the grille rod connectors Danger of jamming Always fix the designer grille roll protector above the convector fan It serves as a protection against reaching into the fan Insert the designer grille roll into the system convector trough Using an Allen key size 3 push the fixing screws to the outside and...

Страница 15: ...nd comply with all current and valid national standards for electrical devices A check of all the electrical components including customer specified safety devices has been successfully performed Switch on the electric circuit for the power supply of the ESK For AR 20xx x S the desired temperature can be set Further information can be found in the user manual of the Alpha Thermostat Operation Use ...

Страница 16: ...t regular cleaning in tervals during normal cleaning Wet Loosen possible grille protectors with a No 3 Allen key as shown Designer Roll Up Grille Roll the cover grill up without bending or kinking Clean in Washing Machine The DR is washing machine safe evenly up to a temperature of 60 C with normal non industrial strength dish washer cleaner After washing and drying the grille can be replaced on t...

Страница 17: ...de Mailing Address Möhlenhoff Wärmetechnik GmbH Techniscal Support Museumstraße 54a DE 38229 Salzgitter Germany All trades participating on the installation connection and com missioning of the ESK need information from this manual in order to perform their work Please ensure that the manual is disclosed correspondingly after the termination of the individual parts of the work Copyright This manua...

Страница 18: ...18 ENG ...

Страница 19: ...19 ENG 8 D24 53 031 12 ESK 180 110 ...

Страница 20: ......

Отзывы: