![Mohawk LMF-12 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/mohawk/lmf-12/lmf-12_manual_1823412010.webp)
MOHAWK MODEL LMF-12, TP-15,TP-16 & TP-18
3
LIFT SPECIFICATIONS
LMF-12/TP-15/TP-16/TP-18 SPECIFICATIONS
LIFT TYPE / TWO POST
ELEC / HYDRAULIC
LIFTING CAPACITY – LMF-12
12,000 LBS.
LIFTING CAPACITY – TP-15
15,000 LBS.
LIFTING CAPACITY – TP-16
16,000 LBS.
LIFTING CAOACITY—TP-18
18,000 LBS
PER ARM CAPACITY – LMF-12
3,000 LBS.
PER ARM CAPACITY – TP-15
3,750 LBS.
PER ARM CAPACITY – TP-16
4,000 LBS.
PER ARM CAPACITY—TP-18
4,500 LBS
LIFTING SPEED (LOADED)
70-80 SECONDS APPROX
LOWERING SPEED (LOADED)
75 SECONDS APPROX
LIFTING HEIGHT (STROKE)
72 INCHES
OVERALL WIDTH
151-1/2 INCHES
WIDTH BETWEEN POST
120 INCHES
WIDTH BETWEEN LIFTING ARMS
102 –7/8 INCHES
POST HEIGHT
104 INCHES
CYLINDER EXTENSION
162 INCHES
OVERHEAD HYDRAULIC LINES
180 INCHES
LIFTING PAD HEIGHT (MIN)
5 INCHES
LIFTING PAD HEIGHT (MAX)
87 INCHES
SHIPPING WEIGHT
3,100 LBS.
POWER UNIT SPECIFICATIONS
BRAND NAME
MONARCH
MODEL M-4509-0191
POWER UNIT TYPE
VERTICAL
MOTOR VOLTAGE
208 / 230
F.L.A. AT RATED CAPACITY
22.5 / 20.4
MOTOR HORSEPOWER
4
MOTOR PHASE
SINGLE
MOTOR CYCLE / HERTZ
60
MOTOR SPEED (R.P.M.)
3450
PUMP FLOW (G.P.M.)
3.2 @ 3450 R.P.M.
RELIEF VALVE SETTING – LMF-12
1650 PSI
RELIEF VALVE SETTING – TP-15
2050 PSI
RELIEF VALVE SETTING – TP-16
2150 PSI
WORKING PRESSURE – LMF-12
1430 PSI
WORKING PRESSURE – TP-15
1800 PSI
WORKING PRESSURE – TP-16
1900 PSI
RESERVOIR CAPACITY
5 GALLONS
HYDRAULIC FLUID MEDIUM
DEXRON III
Performance Table
0
2000
4000
6000
8000
10000
12000
14000
16000
0
500
1000
1500
2000
Pump Pressure (PSI)
Loa
d (
L
B
S
)
SUGGESTED SITE SELECTION / BAY SIZE
WIDTH DEPTH
HEIGHT
15 FEET
30 FEET
15 FEET
NOTE
THE PLACEMENT OF THE UNIT IS DETERMINED BY THE TYPE
(LENGTH, WIDTH, HEIGHT) OF VEHICLE BEING SERVICED.
WEJ-IT ANCHOR SPECIFICATIONS
LENGTH DRILL
DEPTH
DRILL
SIZE
DRILL SIZE
MIN. MAX.
TORQUE
6 IN.
THRU
3/4 IN.
.775 IN. .787 IN.
SEE
ANCHOR
SPECS
PRE-EXISTING FLOOR REQUIREMENTS
MINIMUM
THICKNESS
MINIMUM COMPRESSIVE
STRENGTH
MINIMUM
AGING
6 - 1/2 IN
4000 P.S.I.
28 DAYS
DO NOT INSTALL ANY MOHAWK LIFT ON ANY SURFACE OTHER
THAN CONCRETE CONFORMING TO THE MINIMUM
COMPRESSIVE STRENGTH, MINIMUM AGING, AND THE
MINIMUM THICKNESS STATED ABOVE.
DO NOT INSTALL ANY MOHAWK LIFT ON EXPANSION SEAMS OR
ON CRACKED, OR DEFECTIVE CONCRETE.
DO NOT INSTALL ANY MOHAWK LIFT ON SECONDARY FLOOR
LEVELS OR ANY SURFACE WITH A BASEMENT BENEATH
WITHOUT WRITTEN AUTHORIZATION FROM THE BUILDING
ARCHITECT. NEVER HAND MIX YOUR OWN CONCRETE.
IF FOR ANY REASON A NEW CONCRETE SLAB SECTION IS
REQUIRED, FOLLOW THE INSTRUCTIONS FOR THE FLOOR
MODIFICATION DATA.
FLOOR MODIFICATION DATA
NEW FLOOR SECTION
THICKNESS SLAB
SIZE
WIDTH X LENGTH
CUBIC
YARDS
12 INCHES
72 INCHES x 168 INCHES
2.1
IF, FOR ANY REASON, A NEW CONCRETE SLAB SECTION IS
REQUIRED, MINIMUM THICKNESS, COMPRESSIVE STRENGTH,
AND PROPER AGING IS MANDATORY.
THE NEW SLAB SECTION MUST BE TOTALLY SURROUNDED BY
AN EXISTING CONCRETE FLOOR THAT IS STRUCTURALLY
SOUND. CERTIFIED STRENGTH DOCUMENTATION SHOULD BE
OBTAINED FROM THE FIRM WHO SUPPLIES THE CONCRETE
MIXTURE AT THE TIME OF THE POUR.
NEVER HAND MIX THE CONCRETE.
REFER TO NEW SLAB
RECOMMENDATIONS SECTION.
Содержание LMF-12
Страница 26: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 19 Figure 1 ...
Страница 27: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 20 Figure 2 ...
Страница 28: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 21 Figure 3 ...
Страница 29: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 22 Figure 4a ...
Страница 30: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 23 Figure 4b ...
Страница 31: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 24 Figure 5 ...
Страница 32: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 25 Figure 6 ...
Страница 33: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 26 Figure 7 ...
Страница 34: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 27 Figure 8 ...
Страница 35: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 28 Figure 9 ...
Страница 36: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 29 Figure 10 ...
Страница 37: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 30 Figure 11 ...
Страница 38: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 31 Figure 12 ...
Страница 40: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 33 ...
Страница 41: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 34 ...
Страница 42: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 35 ...
Страница 43: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 36 ...
Страница 44: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 37 ...
Страница 45: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 38 ...
Страница 46: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 39 ...
Страница 47: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 40 ...
Страница 48: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 41 ...
Страница 49: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 42 ...
Страница 50: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 43 ...
Страница 51: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 44 ...
Страница 52: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 45 ...
Страница 53: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 46 ...
Страница 55: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 48 ...
Страница 56: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 49 ...
Страница 57: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 50 ...
Страница 58: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 51 ...
Страница 59: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 52 ...
Страница 60: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 53 ...
Страница 61: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 54 ...
Страница 62: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 55 ...
Страница 63: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 56 ...
Страница 68: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 61 ...
Страница 69: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 62 ...
Страница 70: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 63 ...
Страница 71: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 64 ...
Страница 72: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 65 ...
Страница 73: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 66 ...
Страница 74: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 67 ...
Страница 75: ...MOHAWK MODEL LMF 12 TP 15 TP 16 TP 18 68 ...