ESI-6121 Rev D © Copyright 03/2022 MOGAS Industries, Inc.
www.mogas.com
ESI-6121 Rev D © Copyright 03/2022 MOGAS Industries, Inc.
www.mogas.com
34
35
FINAL PACKING RING
If there is enough depth for the second anti-extrusion
ring
09B
to fit flush in the pocket, install the anti-
extrusion ring
09B
.
If there is not enough depth for the second anti-
extrusion ring
09B
to fit flush in the pocket, do not
install the anti-extrusion ring
09B
.
Use the gland flange
07
to compress the packing
rings enough to fit the second anti-extrusion ring
09B
flush into the pocket. Make sure scribe line of stem is
lined up with scribe line of packing gland.
To do this, install the gland flange
07
.
Apply anti-seize compound onto gland studs
12
and
gland nuts
15
.
Install the gland nuts
15
, tightening all nuts evenly
until there is enough depth for the second anti-
extrusion ring to fit flush into the pocket.
Once this is accomplished, remove the gland nuts
15
and the gland flange
07
.
Install the second anti-extrusion ring
09B
.
INSTALL GLAND FLANGE
Make sure gland studs
12
are in place. If necessary,
install gland studs
12
, using anti-seize compound.
Install gland flange
07
over stem
05
and gland studs
12
.
Apply anti-seize compound onto gland studs
12
and
gland nuts
15
.
Install gland nuts
15
, and torque all nuts
evenly
per
the specifications included with the
test certificate
for each individual valve serial number.
CAUTION!
The gland flange
must
be pulled down evenly to
prevent “cocking” or side loading, as this could
cause damage to the packing and prevent the
valve from operating properly.
Watch the gland flange to ensure that it remains
perpendicular
to the stem, and the gap around
the stem remains
concentric
during the tightening
process.
Do not over-tighten nuts. Torque all nuts
evenly
per the specifications included with the
test
certificate
for each individual valve serial number.
THIS WILL AFFECT THE VALVE WARRANTY.
INSTALL FLANGE BUSHING
Insert the flange bushing
16
.
If necessary, tap into place using a hammer and a
brass or aluminum rod or wooden block.
INSTALL OPERATOR
Refer to
Install Operator – Manual Adaption
(Handlever)
(page 10) or
Install Operator – Actuator
Adaption
(page 14) as required.
07
15
09B
07
12
15
16
Replace Stem Packing
Replace Stem Packing
9
10
!
11
12