ESI-6121 Rev D © Copyright 03/2022 MOGAS Industries, Inc.
www.mogas.com
ESI-6121 Rev D © Copyright 03/2022 MOGAS Industries, Inc.
www.mogas.com
22
23
CAUTION!
It is
extremely important
to follow these steps to
ensure maximum valve performance.
MOGAS does not recommend removing the
operator while valve is subject to operating
conditions.
THIS WILL AFFECT THE VALVE WARRANTY.
!
These procedures apply only to manual adaption
(handlever) supplied by MOGAS or a MOGAS
authorized distributor.
Note:
Valve item numbers shown in
bold
correspond with items shown in the
Valve Item Reference Number, Manual Adaption
section (pages 4 and
5) of this document.
REMOVE HANDLEVER
Remove hex head screw
25
holding handlever
53
in
place.
Note:
Some installations may require removal of washer.
Remove handlever
53
.
STOP POSITIONS
In most cases, it is recommended to leave the
mounting flange adaptor
51
in place to maintain
accurate
open
/
closed
stop positions.
REMOVE STEM ADAPTOR
Remove stem adaptor
13
by lifting or prying upward
as required.
REMOVE FLANGE BUSHING
Remove the flange bushing
16
by driving it upwards
and off the mounting flange
14
, using a hammer and
brass or aluminum rod if necessary.
REMOVE KEYS
Remove keys
06
from stem
05
keyways.
53
25
51
13
16
14
Remove Operator
Manual Adaption (Handlever)
Remove Operator
Manual Adaption (Handlever)
1
2
3
4