CONVEYOR SETUP
Refer to Figures 1, 4 - 7 for visual assistance with the following instructions.
1. Set the conveyor and DMC-B on a suitable table or workbench arranged with the
DMC-B behind the conveyor. See Figure 4.
2. Join the off track to the handle grip on the left hand side of the conveyor using the
screws provided in the handle. See Figure 5.
3. Connect the gray phone type communication cable by inserting the ends into the
rear mounted communication receptacles on the conveyor and the dispenser. See
Figures 1 & 6.
NOTE:
The plug’s release key tab must be properly mated with the
socket’s key slot for proper seating. A fully engaged plug is locked into the socket
and can be removed only by depressing its key tab.
4. Install the dispense head holder onto the conveyor noting the alignment with the
positioning arrow. See Figure 7.
5. Mount the dispense head onto the holder’s cross piece by guiding the two mounting
thumbscrews into the slot and pushing fully inward until contact is made with the
holders upright. Tighten screws. Thumbscrew heads must be on the right side of
the cross piece.
CONVEYOR SETTINGS
1. Column Format Switch is located on the back of the conveyor to the right of the
communication cord socket. This control sets the number of times the conveyor will
stop per plate. Set the switch to 12 for typical DMC-B operations.
Column Format Selector Switch
- sets the plate advancement steps.
Set to 3 when using 4 x 8 port manifold (3 dispensing stops per plate)
Set to 6 when utilizing 2 x 8 port manifold (6 dispensing stops per plate)
Set to 12 when utilizing 1 x 8 port manifold or dispense head (12 dispensing stops per plate)
2. Conveyor Belt Speed Dial is located to the right of column format switch on the back
of the conveyor. This control regulates the speed of the plate moving belt.
3. Conveyor Start / Stop Button is located on the front of the conveyor under the red
power indicator. This control starts and stops all dispensing programs.